How To Calibrate The Flow Rate - Fetco CBS-2151XTS User Manual

Hide thumbs Also See for CBS-2151XTS:
Table of Contents

Advertisement

Set the flow rates of components to adjust for taste profile and for over or under potting.
Built-in algorithms in Brewer controller software corrects brew parameter to customer preferences or to trim variations in flow control components
NOTICE: This operation requires operator hold finger on keypad position for one minute—without lifting it.
1) MEASURE THE FLOW RATE:
-Enter programming mode, scroll left to "OUTPUTS"
-Scroll down to "Left(or)Right Valve Test"
-Place 5 liter/2gal measuring container under empty brewbasket.
One good way to measure is to weigh the test water. Use a scale for at least 5 kg/12lb
-Press To Test the Brew Valve.
It is very important for this test to keep finger in place for the entire minute.
Measure the results of the flow in the 5-liter measuring container and hold the number.
2) AUTOMATIC Built-in CALIBRATE THE FLOW RATE
-Enter this number, in milliliters, into the calibration slider for the Valve tested in the OUTPUT MENU.
-Use milliliters. If measured in fluid ounces (fl.oz) multiply by 29.57 to convert to milliliters
-After entering the measured volume, exit PROGRAMMING and return to the normal screens
3) MANUAL METHOD Operator input: CALIBRATE THE FLOW RATE
Use the amount measured, in milliliters, divided by programmed value and multiply by the current setting
3400 ml p m
CBS-2150 brew
|_________[]________|
3000
3800
valve slider
Obtain programmed volume from "PROGRAM" Menu under "Batch Summary".
Note—match correct batch number to correct side, if two sided.
By entering the new flow rate number into the brewer, the software automatically corrects the valve flow discrepancy
1. The XTS_Series coffee brewers include a hot water convenience tap for single cup beverage purposes.
2. Single use delivery volume should not exceed maximum 16fl.oz/473cc.
3. Water dispensed from this faucet is very hot, up to 205°F/96°C
For factory or qualified service professional use only

How to calibrate the flow rate

!
Keep finger on touchpad for one minute! !!DO NOT STOP!!
Actual Volume
Example of
Programmed Volume
Hot water convenience tap
CURRENT
X
SETTING
11
Enter new setting on
NEW
=
the slider shown and
SETTING
EXIT to save