4 channel 720p 25fps
Table of Contents

Advertisement

Set the COM type, COM device and baud rate in COM Setting interface.
Set the PTZ Protocol and address code. (Default PTZ address code correspond to
channel number. It means the address code of first channel is 1.)
Note: The PTZ protocol, baud-rate and address code should be the same with Dome Camera
Protocol.
Switch the channel which you want to control PTZ to whole screen. Press the "PTZ" key on
the remote controller to get in the PTZ control mode, then you can use the remote controller
to control the PTZ, press "PTZ" again you can quit the PTZ control mode; You can long press
"PLAY/PTZ" button in DVR front panel (3 seconds) or right click the mouse to enter the PTZ
control interface.
Note: Setting and calling preset point by the remote controller:
Enter the PTZ status, press the direction button make the PTZ turn the direction which you want to
set as preset point, press "*preset" button on remote controller and input the No.
of the preset point in the text field, such as 001, then turn the PTZ to another direction, if you press the
"#call" button and input the No. 001 which you preset to the text field, the PTZ
will turn to the 001 preset point automatically.
Note: value range 1-255, 255 means close: Drag the interface to move it.
15.9 Crusie Setting
Click "Cruise setting" in PTZ control interface to enter into setting interface, set related multi-
preset point crusie parameter:
(Note: Function only available when DVR in lock status!)
(1) Cruise interval time: 0-99s.
(2) Preset No.: each channel can max set 16 preset position.