Showtec Showtec LED Light Bar RGB Product Guide ™ Warning.................…...……………..…………………………….………..…. Safety-instructions………………………………………………………………………………………………………… Operating Determinations.…………………………………………………………………………………………….. Rigging.…………………………………………………………………………………………………………………….. Return Procedure……………………………………………………………………………........Claims……………………………………………………………………………............Description................…...………………………………………….………..… Features and Overview ………………………………...….……………….………….……………………….……… Backside……………………………………………………………………………………………………………………. Installation................…...…………………………………….………………… Set Up and Operation..............……..…………………………………….……….. LED Light Bar RGB ............………………………………………………..…….. Multiple LED Light Bar RGB’s..............……………………………………..…….. DMX-Protocol…...........……………………………………………………………………..…. Control Panel….....……........…………………………………………………………………...
WARNING CAUTION! Keep this device away from rain and moisture! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! SAFETY INSTRUCTIONS Every person involved with the installation, operation and maintenance of this device has to: be qualified follow the instructions of this manual CAUTION! Be careful with your operations.
Always let the installation be carried out by an authorized dealer ! Procedure: If the LED Light Bar RGB is lowered from the ceiling or high joists, professional trussing systems have to be used. Use a clamp to mount the LED Light Bar RGB, with the mounting-bracket, to the trussing system.
Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. Call Highlite 0031-455667723 or mail aftersales@highlite.nl and request an RMA prior to shipping the fixture.
• Selectable 3, 9 and 3 (P3CH:Built-in programs) DMX channel operation NOTE: Knowledge of DMX is required to fully utilize this unit. Overview Fig. 1 1) Adjustment Screw + Mountingbracket for Truss mounting 2) Total LED Light Bar RGB 252 LEDS Backside Fig. 2 3) Power In 4) Ground...
Before plugging the unit in, always make sure that the power supply matches the product specification voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa. One LED Light Bar RGB 1. Fasten the effect light onto firm trussing.
DMX Protocol Control Panel When the indicator light is on, means the LED Bar is working Fig. 4 A. LED Display D. Up Button B. MODE Button E. Down Button C. SETUP Button Control Mode The fixtures are individually addressed on a data-link and connected to the controller. The fixtures respond to the DMX signal from the controller.
Now the device will play its built-in programs automatically. DMX Operation The LED Light Bar RGB’s built-in controller will automatically detect the presence of a DMX signal. In order to receive a DMX signal, the built-in controller must be attached to a DMX controller by a 3-pin DMX cable and the DMX controller must be turned on.
Master / slave addressing Master 1) The default setting for this device is master. 2) Only one fixture can be the master. Note: Disconnect the fixture from the DMX controller before master/slave operating, otherwise data collisions may occur and the fixtures will not work properly! In master/slave mode, the master fixture can execute the built-in programs, all the slave fixtures will work the same.
3 DMX Channels Channel 1 – Red 0-255 Gradual adjustment Red from 0 – 100% Channel 2 – Green 0-255 Gradual adjustment Green from 0 – 100% Channel 3 – Blue 0-255 Gradual adjustment Blue from 0 – 100% 9 DMX Channels Channel 1 –...
Page 13
3 DMX Channels (Built-in Programs) Channel 1 – Built-in Program / Sound-controlled 0-17 Program 00 18-35 Program 01 36-53 Program 02 54-71 Program 03 72-89 Program 04 90-107 Program 05 108-125 Program 06 126-143 Program 07 144-161 Program 08 162-179 Program 09 180-197 Program 10...
3. If all of the above appears to be O.K., plug the unit in again. 4. If you are unable to determine the cause of the problem, do not open the LED Light Bar RGB, as this may damage the unit and the warranty will become void.
Page 15
Problem Probable cause(s) Remedy No power to the fixture · Check that power is switched on One or more and cables are plugged in. fixtures are Primary fuse blown. · Replace fuse. completely dead. Fixtures reset The controller is not connected. ·...