BOILER CONTROLS / DISPLAY
Standby Mode
If the boiler has been switched to Standby Mode the following screen will be displayed
No Boiler operation will take place with this setting. See Frame 38 to change to Summer or Winter
setting
Summer Mode
If the boiler has been switched to Summer Mode a screen similar to the following will be displayed
(line 5 may vary depending on setup)
Domestic Hot Water operation will take place with this setting but Central Heating will not.
See Frame 38 to enable Central Heating by changing to Winter setting
Winter Mode
If there is no current Heat Demand a screen similar to the following will be displayed (line 5 may vary
depending on setup)
Line 5 indicates "Switched Live" or "OpenTherm" or "0-10V" depending on which controls are
connected to the boiler
Domestic Hot Water Mode (DHW Thermostat)
If there is an ongoing Domestic Hot Water Demand using a DHW
Thermostat screens similar to the following will be displayed
Line 2 indicates whether Switched Live or OpenTherm is
controlling the boiler
Line 3 indicates the current operating State (Pre-Purge or Ignition
or Burner On or Pump Overrun)
Burner Power and Flow Temperature will vary as the boiler
operates
Central Heating Mode
If there is an ongoing Central Heating Demand screens similar to
the following will be displayed
Line 2 indicates whether Switched Live or OpenTherm is
controlling the boiler
Line 3 indicates the current operating State (Pre-Purge or Ignition
or Burner On or Pump Overrun)
Outside temperature will only be shown if an outside sensor is
connected to the boiler
Burner Power and Flow Temp will vary as the boiler operates
See Frame 38 for adjusting Flow Setpoint
Boiler Frost Protection Mode
If the boiler flow temperature drops below 5°C screens similar
to the following will be displayed
Line 3 indicates the current operating State (Pre-Purge or
Ignition or Burner On or Pump Overrun)
Outside temperature will only be shown if an outside sensor
is connected to the boiler
Burner Power and Flow Temp will vary as the boiler operates
User's
Hot Water
DHW Switched Live On
Burner On
DHW Thermostat
Flow Temp
80°C
Central Heating
CH Switched Live On
Burner On
Flow Setpoint
80°C
Flow Temp
80°C
Boiler Frost Protect
Burner Power
100%
Burner On
Frost Setpoint
5°C
Flow Temp
80°C
Standby Mode
For Central Heating
select Winter Mode
For Hot Water
select Summer or Winter
Summer Mode
For Central Heating
select Winter Mode
No Hot Water Demand
Switched Live
Off
Winter Mode
No Central Heating
Demand
No Hot Water Demand
Switched Live
Off
Hot Water
Burner Power
100%
Burner On
DHW Thermostat
Flow Temp
80°C
Central Heating
Burner Power
100%
Outside Temp'
10°C
Flow Setpoint
80°C
Flow Temp
80°C
Boiler Frost Protect
Burner Power
100%
Outside Temp'
10°C
Frost Setpoint
5°C
Flow Temp
80°C
3