Download Print this page

DeWalt DW005K Manual page 18

24v rotary hammer

Advertisement

NiMH JETSTREAM Components
Centrifugal Fan:
3
0.6m
/min Cooling
• The fan will turn on for appx. 6 seconds when powered from the AC mains
• The fan stays on during hot pack delay, fast charge, and equalization charge.
• Below 10°C pack temperature the fan stays off
• In standby the fan turns on occasionally to blow off dust
24V
2.5Ah Output
• DE0245 remains for
NiCD in 2002
• DE0246 optimised for
charging NIMH (+NiCD)
DE0245 not capable of
charging NIMH due to
thermal damage

Advertisement