Gp2R Power Measure Summary - LG 60PA6500 Service Manual

Hide thumbs Also See for 60PA6500:
Table of Contents

Advertisement

3. GP2R Power measure Summary

Power Line
Voltage Spec [V]
+5V_ST
4.845~5.355
+5V_ST_EN
4.845~5.355
+3.3V_AVDD
+2.5V_AVDD
+1.5V_DDR_IN
1.425~1.575
+1.26V_VDDC
+3.3V_ST
3.234~3.366
+17V
16.15~17.85
+5V_TU
+5V
4.845~5.355
+3.3V_TU
+1.2V_TU
Copyright © 2011 LG Electronics Inc. All rights reserved.
Only for training and service purposes
Voltage [V]
Ripple spec [Vpp]
5.01
5.00
3.14~3.6
3.31
2.38~2.62
2.53
1.57
1.2~1.32
1.27
3.30
17.03
4.75~5.25
4.99
5.03
3.15~3.46
3.26
1.20~1.32
1.27
Ripple [mV]
86
17
0.5
15
20
1.5V +/-5%
20
30
0.5
19
1.09A
None
20
57
None
26
None
21
Current [A]
Remark
0.009
0.710
0.285
0.200
0.310
0.770
0.024
1.420
0.170
2.600
0.320
0.300
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents