Maintaining Fuel Valve - Ford FG3050P Operator's Manual

Hide thumbs Also See for FG3050P:
Table of Contents

Advertisement

Carburetor Adjustment
The carburetor is low emission and is equipped with a non-adjustable idle mixture valve. If adjustment is needed contact
an authorized dealer.
Replacing Fuel Filter (See Fig 18)
Occasionally the fuel filter may become clogged and need replacing. To purchase a replacement fuel filter contact PULSAR
customer service or your local small Engine repair shop.
Turn the fuel valve to the "OFF" position.
Remove the fuel line from both sides of the filter by squeezing the ends of the retaining clip with pliers.
Slide the fuel line off.
Replace with new fuel filter.
Reinstall fuel lines to new fuel filter.
Turn the fuel valve to the "ON" position.
Fuel tank must be empty before replacing fuel filter. Run unit until tank is empty, if needed,
CAUTION!
or inspect filter prior to fill-up.
Draining Fuel Tank and Carburetor
To help prevent gum deposits in the fuel system, drain the fuel from the tank and carburetor before storing the unit for long
periods of time. This will help prevent starting problems in the future. If the unit is stored with fuel and the fuel becomes
stale or turns gummy or to varnish the warranty does not cover this repair or service.
Draining the fuel tank
Turn the engine OFF.
Turn the fuel valve to the OFF position.
Remove the fuel line that leads to the carburetor from the petcock by squeezing the ends of the hose clamps and
sliding the fuel line off.
If needed, install a fuel hose that will extend to a suitable fuel container large enough to catch the fuel being drained
from the tank.
Turn the fuel valve to the ON position.
When the fuel has drained from the tank, close the fuel valve and reinstall fuel line securely on petcock.
Fig 17
MAINTENANCE