Table 3-3. Initial Storage Array Setup Tasks (continued)
Task
Set up alert
notifications.
• Set up e-mail alerts.
• Set up SNMP alerts.
The Status area in the
Summary tab shows if
alerts have been set for
the selected array.
Configure the iSCSI Ports on the Storage Array
By default, the iSCSI ports on the storage array are set as given below.
IPv4 Addresses (Default IP addresses):
Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask: 255.255.255.0
Port: 3260
Controller 0, Port 1: IP: 192.168.131.101 Subnet Mask: 255.255.255.0
Port: 3260
Controller 1, Port 0: IP: 192.168.130.102 Subnet Mask: 255.255.255.0
Port: 3260
Controller 1, Port 1: IP: 192.168.131.102 Subnet Mask: 255.255.255.0
Port: 3260
44
Preparing Your Systems for Clustering
Purpose
To arrange to notify
individuals (by e-mail) and/or
storage management stations
(by SNMP) when a storage
array component degrades or
fails, or an adverse
environmental condition
occurs.
Information Needed
E-mail — Sender
(sender's SMTP gateway
and e-mail address) and
recipients (fully qualified
e-mail addresses)
SNMP —
1
A community name
2
A known set of storage
management stations
set by administrator as
an ASCII string in the
management console
(default: "public")
3
A trap destination
4
IP address or host name
of a management
console running an
SNMP service