Installation instructions

GB
12
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
Installation IS 360 D TRIO
insert the dowels. In order
y Ceiling mounting
to be able to perform a
Warning: installation
switching operation, a
involves a mains connec-
two-phase power supply
tion. With 230 V, a risk of
lead must run to the con-
electrocution exists!
sumer. The rubber plugs
Therefore, switch off the
can be pierced for this
power first and check
purpose with a screwdriv-
freedom from voltage with
er. For surface-mounted
a voltage tester.
wiring, two punching
Installation of the sensor
holes are provided on the
involves work on the
housing cover
mains power supply; this
can easily be pierced.
work must therefore be
After passing the wiring
carried out professionally
through, the mounting
in accordance with regu-
plate can be screwed in
lations. Please note that
place. Finally, reapply and
the motion detector must
engage the housing cover
be protected by a 10 A
5
.
circuit breaker. The instal-
lation site should be at
y Connection of the mains
least 50 cm from a light,
lead
since the latter's heat
The mains lead consists
radiation could result in
of a 2-3 phase cable.
false triggering of the sen-
L
= phase conductor
sor. Remove the decora-
tive blind
5
by pressing
the two indentations gen-
N = neutral conductor
tly. At the same time turn
the decorative blind
PE = protective-earth
counter-clockwise and
pull. Undo the two fasten-
ing screws
1
by turning
If in doubt, the cable must
counter-clockwise and
be identified with a volt-
remove the mounting
age tester. Switch off the
plate. Do not undo the
current again. The wire
internal wiring to the ter-
terminals are for the
minal block, but extract
mains lead. The phase
the block by pulling it
conductor (L) is connec-
gently. Insert the rubber
ted from above to the first
plugs into the mounting
terminal (see arrow) and
plate. Hold the mounting
the neutral conductor (N)
plate against the ceiling
to the second terminal. If
and mark the drill holes,
the green/yellow protec-
paying attention to the
tive-earth conductor is
wiring arrangement in the
present, connect this to
ceiling), drill the holes and
blue
black/brown
green/yellow
the bottom terminal
provided.
y Connection of the
service lead
The service lead (e.g.
light) likewise consists of
a 2-3 phase cable which
is connected to terminals
N and L'. The phase con-
ductor of the consumer
(black or brown cable) is
5
. These
connected to the terminal
marked L'. The neutral
conductor (blue cable) is
clamped to the terminal
marked N together with
the mains lead neutral
conductor. Connect any
green/yellow protective-
earth conductor to the
lower terminal.
Important: Getting the
cable connections
crossed will produce a
(usually black
short circuit in the unit or
or brown)
in your fuse box. In this
case, the individual wires
must be re-identified and
(usually blue)
reconnected. A mains
conductor
switch for ON and OFF
(green/yellow)
switching can of course
be installed in the mains
lead.