Troubleshooting
Malfunction
Cause
Fuse has blown; not
IS 360 D TRIO without power
y
switched on
Short-circuit
y
y
Twilight setting in night-
IS 360 D TRIO does
time mode during
not switch on
daytime operation
Bulb burned out
y
y
Power switch off
y
Fuse blown
y
Detection zone not
correctly adjusted
y
Continued movement
IS 360 D TRIO does
within the detection zone
not switch off
Switched on light is within
y
detection zone and swit-
ches on again as a result
of temperature change
Set to continuous
y
operation by indoor
series switch
y
Switched on light is
IS 360 D TRIO keeps
within detection zone
switching ON/OFF
Animals moving in
y
detection zone
y
Wind is moving trees
IS 360 D TRIO switches
and bushes in the
on when it should not
detection zone
y
Cars in the street
are detected
y
Sudden temperature
changes due to weather
(wind, rain, snow) or
exhaust air from fans or
open windows
18
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
Remedy
Replace fuse, switch on
y
mains switch, check
wiring with voltage tester
Check connections
y
y
Adjust setting
Replace light bulb
y
y
Switch on
y
Replace fuse, check
connection if necessary
y
Readjust
y
Check zone and readjust
if necessary or apply
shroud
Readjust zone or apply
y
shroud
Series switch to
y
automatic
y
Adjust detection zone or
apply shrouds, increase
distance
Adjust zone or apply
y
shrouds
y
Adjust zone or apply
shrouds
y
Adjust zone or apply
shrouds
y
Adjust detection zone or
install in a different place

Technical specifications

Dimensions (H x W x D):
100 x 120 x 120 mm
Output:
Filament bulbs, 1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max., at cos ϕ = 0.5,
inductive load at 230 V AC
6 x 58 W each max., C ≤ 132 µF
at 230 V AC *1)
Connection:
230 – 240 V, 50 Hz
h
Angle of coverage:
360
Pivoting range of the sensor:
Fine adjustment ± 10°
Reach:
max. 12 m (electronically stabilised)
Time setting:
10 sec. – 15 min.
Twilight setting:
2 – 2000 lux
IP rating:
IP 54
Safety class:
II
Temperature ranging from:
- 20° C to + 50° C
*1) Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast (total capacity of all connected
ballasts below the value specified).
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC.
Functional warranty
This STEINEL product has
This warranty shall not
been manufactured with
cover damage to wearing
great care, and its operation
parts or damage and faults
and safety have been tested
caused by incorrect opera-
in conformity with the current
tion or maintenance.
regulations. Production is
Breakage due to a fall is
also submitted to final
also not covered.
random-sample testing.
Further consequential dam-
STEINEL undertakes the
age to external items is
guarantee for perfect condi-
excluded.
tion and function.
Claims under warranty shall
The warranty period is 36
only be accepted if the
months, starting on the date
product is sent fully assem-
of sale to the user. We
bled and well packed com-
undertake to remedy faults
plete with sales slip or
caused by material or manu-
invoice (date of purchase
facturing defects. This war-
and dealer's stamp) to the
ranty undertaking shall be
appropriate Service Centre
performed by the repair or
or handed in to the dealer
replacement of the defective
within the first 6 months.
parts, at our own discretion.
h
(with 180
angle of aperture)
Repair Service:
Our Customer Service
Department will repair faults
not covered by warranty or
after the warranty period.
Please send the product
well packed to your nearest
Service Centre.
19

Advertisement

Table of Contents
loading

Table of Contents