System Components; Technical Specifications - STEINEL IS 2180 ECO Installation Instructions Manual

Hide thumbs Also See for IS 2180 ECO:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
GB Installation instructions
Dear Customer,
Congratulations on purchas-
ing this STEINEL Infrared
Sensor and thank you for
the confidence you have
shown in us. You have cho-
sen a high-quality product
that has been manufac-
tured, tested and packed
with the greatest care.

System components

1 Security screw
2 Front cover
3 Lens (can be removed
and turned for selecting
the max. basic reach
settings of 5 m or 12 m)

Technical specifications

Dimensions (H × W × D):
Output:
Incandescent / halogen lamp load
Fluorescent lamps, electronic ballast
Fluorescent lamps, uncorrected
Fluorescent lamps, series-corrected
Fluorescent lamps, parallel-corrected
Low-voltage halogen lamps
Connection:
Detection angle:
Sensor reach:
Time setting:
Light threshold:
Enclosure:
Temperature range:
Please familiarise yourself
with these instructions
before attempting to install
the sensor since prolonged
reliable and trouble-free op-
eration will only be ensured
if it is installed properly.
4 Light threshold setting
control 2-2000 lux
5 Time setting control
10 sec. - 15 min.
LED < 2 W
2 W < LED < 8 W
LED > 8 W
Capacitive load
120 × 78 × 55 mm
2000 W
1000 W
500 VA
406 VA
406 VA
1000 VA
16 W
64 W
64 W
132 μF
230-240 V, 50 Hz
180° horizontal, 90° vertical
basic setting 1: 5 m max.
basic setting 2: 12 m max. (factory setting)
+ precision adjustment from 1 – 12 m by means
of clip-on shrouds
10 sec. - 15 min. (factory setting: 10 sec.)
2-2000 lux (factory setting: 2000 lux)
IP 54
-20°C to +50°C
– 12 –
We hope your new Infrared
Sensor will give you lasting
satisfaction.
6 Clip (housing can be
flipped up for assembly
and connection to mains
power supply)

Advertisement

Table of Contents
loading

Table of Contents