Content Wiring and Connections ...................... 4 Setting up the speed ......................6 Operating voltage ........................ 7 Battery protection system ....................8 Protections and alarms ......................9 FRCC.PI.044.A1.02...
Wiring and Connections General rules GLT80TDC must always be powered through The unit is protected against damage caused by the dedicated electronic driver FDC3, which wrong polarity of the supply. The compressor will is supplied with the compressor as a separate not run correctly if it’s wrongly connected.
Wiring and Connections Wiring Diagram The FDC3 electronic driver features a terminal board where all connections are made. The terminal layout is described in Fig. 1: Fig 1. FDC3 wiring scheme FUSE FDC3 ELECTRONICAL DRIVER 24÷42V BATTERY ELECTRONIC INTEGRAL MANAGER FAN 12V ALARM SWITCHER...
SPI to set nearest speed set up from table 2. Replacing a different 1. Check for compressor displacement D and set up GLT80TDC speed by programming (if brand DC compressor Speed S . Then calculate the required velocity of...
Operating voltage GLT80TDC is designed to operate in a wide range The output power is 450W (Nominal) 500W of DC voltages, supplied either by a battery or by (Maximum). 12-14V systems the output power any other kind of filtered DC power supply.
Battery protection system There is a protection system for the battery 12V system: cut-out = 10.0V; cut-in = 11.5 V that prevents the compressor from operating if 24V system: cut-out = 22.0V; cut-in = 24.5V the available voltage becomes too low. Battery 42V system: cut-out = 36.0V;...
Protections and alarms GLT80TDC is electronically protected against a • Electronic driver overheat: if the temperature number of possible dysfunctions and failures: of the electronic components of the control becomes too high, an internal sensor will stop • Battery discharge.