  • Page 1 INSTALLATION GUIDE INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.2...
  • Page 2: What's In The Box

    What’s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 3: Table Of Contents

    RS485 Connection .............. Restore factory setting ............DIP Switch Setting ..............RS485 Address ................Terminal Resistance ..............Installation Diagram ............Troubleshooting ..............PC 485 Setting Table ............Electrical Specifications ........... Specifications ................InBio Pro Series Access Control Panels INSTALLATION GUIDE...
  • Page 4: Optional Accessories

    Optional accessories Wiegand Card Reader Prox Card RS485 Convertor K2 Exit Button CR20E Card Enroller ZK4500 Enrollment reader RS485 Fingerprint Reader InBio Pro Cabinet InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 5: Safety Precautions

    Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. Contact your supplier in case of a problem. InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 6: Product Pin Diagram

    Product PIN Diagram Figure 1 InBio Pro Series Access Control Panels INSTALLATION GUIDE...
  • Page 7: Led Indicators

    Figure 6 Flashing (RUN) Green LED indicates that panel is in normal working state. Figure 7 Flashing (CARD) Yellow LED indicates that the card is read by the panel. Figure 8 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 8: Product Dimension

    4.17 in (106 mm) 4.17 in (106 mm) 1.42 in (36 mm) Figure 9 InBio Pro- Metal Cabinet 13 in (330 mm) 15.7 in (400 mm) 3.56 in (90.5 mm) Figure 10 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 9: Installation Of Panel & Cabinet

    Inserting Panel to Rail Mounting Rail Figure 12 We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be found, then use the supplied drywall plastic mollies (anchors). InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 10: Wiring Legend

    Wiring Legend Figure 13 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 11: Power Wiring Diagram

    Power Wiring Diagram Without Backup Battery ground Switching Power Supply Figure 14 With Backup Battery ground Switching Power Supply Figure 15 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 12: Rs485 Fingerprint Reader Connection

    RS485 Fingerprint Reader Connection EThERNET 12V DC 12V DC RS485 Fingerprint Reader Figure InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 13: Dip Switch Setting For Rs485 Reader

    RS485 address 2 is for OuT reader) 200 meters or 600 ft , the number 6 switch should be ON as below: If RS485 fi ngerprint reader is pow- Distance: More than 200 meters InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 14: Wiegand Connection

    Wiegand Connection DC+(6-14V) Wiegand D0 Wiegand D1 green LED Beeper Wiegand Card Reader Figure 18 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 15: Rex Connections

    REX Connections Separate Power Supply Separate Power Supply 12V DC(+) 12V DC( - ) BuTTON unused ZK ABK Exit Button K2 Exit Switch Figure 19 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 16: Lock Connection

    Lock Connection Connecting a Lock with External to Power Supply (Dry Contact) EThERNET Door Contact Sensor Sensor Sensor 12V DC FR107 Diode Figure 20 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 17: Switching Dry Contact To Wet Contact

    Connect the lock as show in the diagram, (see fi gure 23 and 24) Back of InBio460Pro Select one Relay Figure 21 Default setting Take off jumpers Jumpers Plug Jumpers 1, 2 - 3, 4 2, 3 - 4, 5 Figure 22 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 18: Lock Connection

    12V DC FR107 Diode 16 or 18 AWG shielded cable recommended 12V DC Figure 23 Normally Closed Lock Powered From Lock Terminal (Wet Contact) EThERNET 12V DC FR107 Diode 12V DC Figure 24 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 19: Aux. I/O Connection

    Aux. I/O Connection Aux. Input Connection EThERNET 12V DC Figure 25 Aux. Output Connection EThERNET 12V DC Figure 26 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 20: Ethernet Connection

    To connect InBio Pro Panel with a PC directly, connect both devices with a straight network cable. As the InBio Pro Panel supports auto MDI/MDIX, it is not necessary to use a crossover type cable. EThERNET CR20E Card Issuer ZK4500 Enrollment reader Figure 28 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 21: Rs485 Connection

    RS485 + #1 InBio Pro Panel #2 InBio Pro Panel #63 InBio Pro Panel RS485 -- RS485 + #1 InBio Pro Panel #2 InBio Pro Panel #63 InBio Pro Panel Figure 31 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 22: Rs485 Connection

    10 seconds and fi nally returned to OFF position, the factory settings will be restored after the access control panel is restarted. To reset factory settings Turn #7 switch ON and OFF Repeat process 3 times Figure 33 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 23: Dip Switch Setting

    Number 8 is for setting the RS485 termination resistance. Putting the switch to ON position is equivalent to parallel connection of a 120 ohm termination resis- tance between 485+ and 485- lines. 120 ohm #63 InBio Pro Panel Figure 35 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 24: Installation Diagram

    Ethernet Communication wire RS485 Network Communication wire 220/110 V Input InBio Pro Access Control Bundle CEILINg Sensor Electric Lock OuTDOOR INDOOR Exit Button Outdoor Wiegand card reader Indoor Wiegand card reader Figure 36 InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 25: Troubleshooting

    When Web Server is used, “user Name“ and “Password“ should be set fi rstly.The default “user name” and “password” are admin. c. Click Sign in to enter the Web Server. 2. Basic Operation Bar of the Web Server InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 26 Confi rm. (3) Use Conditions of the Server Click , and you can view the version of the current server, as well as the browser and resolution recommended for the server. InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 27 If you met some problems when using the server, click to view or down- load the user help document. (5) Exit Click , and then click Confi rm to return to the server login page. InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 28: Communication Settings

    IP Mode: the default server IP is 0.0.0.0, and you can modify it according to the actual. Port: the default gateway is 80, and you can modify it according to the actual. InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 29 4. System (1) User Settings Click Edit to change the login password of an administrator or a user. InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 30 PC time, and click Confi rm to complete the setting.. (3) System Settings Click Reboot. The device will be restarted. (4) Device Information you can view the basic information, remaining capacity, and network information of the current device. InBio Pro Series Access Control Panels INSTALLATION guIDE...
  • Page 31 Figure 34 2. Can we integrate IP Camera and NVR? › Currently ZKBiosecurity software supports ZKTeco’ s IP Cameras and NVR › you can associate a camera to the door and setup a linkage for the same. 3. What does it mean when I get a “Wiegand Format Error”? ›...
  • Page 32: Pc 485 Setting Table

    PC 485 Setting Table Switch Setting Address No. InBio Pro Series Access Control Panels INSTALLATION GUIDE...
  • Page 33 Switch Setting Address No. InBio Pro Series Access Control Panels INSTALLATION GUIDE...
  • Page 34: Electrical Specifications

    The input ports are pulled Pull- up resistance (Ω) 4.7k up with 4.7k resistors WIEgAND INPuT Voltage (V) 10.8 13.5 Current (mA) ZK ELECTRIC LOCK Voltage (V) DC 10.8 13.2 Current (mA) InBio Pro Series Access Control Panels INSTALLATION GUIDE...
  • Page 35: Specifications

    Mounting Wall Mount Dimensions (Bundle Only) 15.7in. x 3.56in. x 13.0in 400mm(L) x 90.5mm(W) x 330mm(h) Dimensions (Board Only) 8.0in. x 4.17in. 203.2mm(L) x 106mm(W) 32 bit 400Mhz 32MB Flash 128MB Certified InBio Pro Series Access Control Panels INSTALLATION GUIDE...
  • Page 36 © Copyright 2015. ZKTeco Inc. ZKTeco Logo is a registered trademark of ZKTeco or a related company. All other product and company names mentioned are used for identification purposes only and may be the trademarks of their respective owners. All specifications are subject to change without notice. All rights reserved.