Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. Contact your supplier in case of a problem. InBio Pro Series Access Control Panels INSTALLATION guIDE...
Figure 6 Flashing (RUN) Green LED indicates that panel is in normal working state. Figure 7 Flashing (CARD) Yellow LED indicates that the card is read by the panel. Figure 8 InBio Pro Series Access Control Panels INSTALLATION guIDE...
4.17 in (106 mm) 4.17 in (106 mm) 1.42 in (36 mm) Figure 9 InBio Pro- Metal Cabinet 13 in (330 mm) 15.7 in (400 mm) 3.56 in (90.5 mm) Figure 10 InBio Pro Series Access Control Panels INSTALLATION guIDE...
Inserting Panel to Rail Mounting Rail Figure 12 We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be found, then use the supplied drywall plastic mollies (anchors). InBio Pro Series Access Control Panels INSTALLATION guIDE...
Power Wiring Diagram Without Backup Battery ground Switching Power Supply Figure 14 With Backup Battery ground Switching Power Supply Figure 15 InBio Pro Series Access Control Panels INSTALLATION guIDE...
RS485 Fingerprint Reader Connection EThERNET 12V DC 12V DC RS485 Fingerprint Reader Figure InBio Pro Series Access Control Panels INSTALLATION guIDE...
RS485 address 2 is for OuT reader) 200 meters or 600 ft , the number 6 switch should be ON as below: If RS485 fi ngerprint reader is pow- Distance: More than 200 meters InBio Pro Series Access Control Panels INSTALLATION guIDE...
Wiegand Connection DC+(6-14V) Wiegand D0 Wiegand D1 green LED Beeper Wiegand Card Reader Figure 18 InBio Pro Series Access Control Panels INSTALLATION guIDE...
REX Connections Separate Power Supply Separate Power Supply 12V DC(+) 12V DC( - ) BuTTON unused ZK ABK Exit Button K2 Exit Switch Figure 19 InBio Pro Series Access Control Panels INSTALLATION guIDE...
Lock Connection Connecting a Lock with External to Power Supply (Dry Contact) EThERNET Door Contact Sensor Sensor Sensor 12V DC FR107 Diode Figure 20 InBio Pro Series Access Control Panels INSTALLATION guIDE...
Connect the lock as show in the diagram, (see fi gure 23 and 24) Back of InBio460Pro Select one Relay Figure 21 Default setting Take off jumpers Jumpers Plug Jumpers 1, 2 - 3, 4 2, 3 - 4, 5 Figure 22 InBio Pro Series Access Control Panels INSTALLATION guIDE...
12V DC FR107 Diode 16 or 18 AWG shielded cable recommended 12V DC Figure 23 Normally Closed Lock Powered From Lock Terminal (Wet Contact) EThERNET 12V DC FR107 Diode 12V DC Figure 24 InBio Pro Series Access Control Panels INSTALLATION guIDE...
To connect InBio Pro Panel with a PC directly, connect both devices with a straight network cable. As the InBio Pro Panel supports auto MDI/MDIX, it is not necessary to use a crossover type cable. EThERNET CR20E Card Issuer ZK4500 Enrollment reader Figure 28 InBio Pro Series Access Control Panels INSTALLATION guIDE...
RS485 + #1 InBio Pro Panel #2 InBio Pro Panel #63 InBio Pro Panel RS485 -- RS485 + #1 InBio Pro Panel #2 InBio Pro Panel #63 InBio Pro Panel Figure 31 InBio Pro Series Access Control Panels INSTALLATION guIDE...
10 seconds and fi nally returned to OFF position, the factory settings will be restored after the access control panel is restarted. To reset factory settings Turn #7 switch ON and OFF Repeat process 3 times Figure 33 InBio Pro Series Access Control Panels INSTALLATION guIDE...
Number 8 is for setting the RS485 termination resistance. Putting the switch to ON position is equivalent to parallel connection of a 120 ohm termination resis- tance between 485+ and 485- lines. 120 ohm #63 InBio Pro Panel Figure 35 InBio Pro Series Access Control Panels INSTALLATION guIDE...
Ethernet Communication wire RS485 Network Communication wire 220/110 V Input InBio Pro Access Control Bundle CEILINg Sensor Electric Lock OuTDOOR INDOOR Exit Button Outdoor Wiegand card reader Indoor Wiegand card reader Figure 36 InBio Pro Series Access Control Panels INSTALLATION guIDE...
When Web Server is used, “user Name“ and “Password“ should be set fi rstly.The default “user name” and “password” are admin. c. Click Sign in to enter the Web Server. 2. Basic Operation Bar of the Web Server InBio Pro Series Access Control Panels INSTALLATION guIDE...
Page 26
Confi rm. (3) Use Conditions of the Server Click , and you can view the version of the current server, as well as the browser and resolution recommended for the server. InBio Pro Series Access Control Panels INSTALLATION guIDE...
Page 27
If you met some problems when using the server, click to view or down- load the user help document. (5) Exit Click , and then click Confi rm to return to the server login page. InBio Pro Series Access Control Panels INSTALLATION guIDE...
IP Mode: the default server IP is 0.0.0.0, and you can modify it according to the actual. Port: the default gateway is 80, and you can modify it according to the actual. InBio Pro Series Access Control Panels INSTALLATION guIDE...
Page 29
4. System (1) User Settings Click Edit to change the login password of an administrator or a user. InBio Pro Series Access Control Panels INSTALLATION guIDE...
Page 30
PC time, and click Confi rm to complete the setting.. (3) System Settings Click Reboot. The device will be restarted. (4) Device Information you can view the basic information, remaining capacity, and network information of the current device. InBio Pro Series Access Control Panels INSTALLATION guIDE...
Page 31
Figure 34 2. Can we integrate IP Camera and NVR? › Currently ZKBiosecurity software supports ZKTeco’ s IP Cameras and NVR › you can associate a camera to the door and setup a linkage for the same. 3. What does it mean when I get a “Wiegand Format Error”? ›...
The input ports are pulled Pull- up resistance (Ω) 4.7k up with 4.7k resistors WIEgAND INPuT Voltage (V) 10.8 13.5 Current (mA) ZK ELECTRIC LOCK Voltage (V) DC 10.8 13.2 Current (mA) InBio Pro Series Access Control Panels INSTALLATION GUIDE...
Mounting Wall Mount Dimensions (Bundle Only) 15.7in. x 3.56in. x 13.0in 400mm(L) x 90.5mm(W) x 330mm(h) Dimensions (Board Only) 8.0in. x 4.17in. 203.2mm(L) x 106mm(W) 32 bit 400Mhz 32MB Flash 128MB Certified InBio Pro Series Access Control Panels INSTALLATION GUIDE...