6-4. Operation And Error Messages
1
1
Alpha−Numeric Display
The following operational messages
may appear:
CHNG OIL
Indicates an oil change is needed. This light
flashes after the first 50 hours of operation
and then at normal oil change intervals
thereafter.
If CHECK ENGINE LED is on, engine oil
change time interval has counted down to
zero, indicating it is time to change engine
oil.
To reset display after oil change, see Sec-
tion 8-5.
If CHECK COMPRESSOR LED is on,
compressor oil change time interval has
counted down to zero, indicating it is time to
change compressor oil.
To reset display after oil change, see Sec-
tion 8-7.
HIGH SPd
Indicates engine is locked in high speed.
With engine running, press Power/Start
button to toggle speed.
AUTOSTOP
This will flash briefly when unit is in Auto On
mode and the engine stops automatically.
The following error messages may ap-
pear:
.
If error message appears, consult
troubleshooting section for remedial
actions.
Hi TEMP
Indicates high compressor temperature if
CHECK COMPRESSOR LED is on.
OM-240 113 Page 22
OVErPRES
Indicates the compressor has an over pres-
sure error.
OVErSPEEd
Indicates an engine over speed error.
LOW OIL
Indicates a low oil pressure condition in the
engine.
NoCHARGE
Indicates an alternator problem.
HiTEMP 1
Indicates high engine temperature if
CHECK ENGINE LED is on. The temperat-
ure switch has indicated high temperature.
HiTEMP 2
Indicates high engine temperature if
CHECK ENGINE LED is on. The temperat-
ure sensor has indicated high temperature.
SPd SENS
Indicates a problem with the engine speed
sensor.
GovCNTRL
Indicates a problem with the engine gov-
ernor control.
SEN OPEN
Indicates coolant sensor is open.
SENSHORT
Indicates coolant sensor is shorted.
ALTRNATR
Indicates an open condition in the alternat-
or.
HiVOLTiN
Indicates high input voltage from the bat-
tery.
LoVOLTiN
Indicates low input voltage from the battery.
ERROR
If an engine error occurs and the engine
shuts down, the error will be stored in
memory. If the display has already turned
off, press the Power push button once to
activate the Remote Panel. If the error is in
memory, the display will read ERROR and
after a few seconds will flash an error code.
See Table 6-1.
EnVertert Power System
The following messages may appear if the
unit is equipped with the EnVertert power
system.
ENVRT hot
Indicates the EnVerter power system is
overheated.
ENVRT com
Indicates a communication error.
ENVRT ok
Indicates the EnVerter power system is
functioning. Press Power/Start button to
enable.
HYdCAbLE
Indicates problem with crane remote inter-
connecting cable, plug, receptacle, or ad-
apter harness.