WEST 8800 Operating Manual page 46

Process controller
Table of Contents

Advertisement

Configuration level
Name
IAda
IExo
ILat
Pass
IPar
ICnf
ICal
CDis3
TDis3
PDis3
T.dis3
T.InF1
T.InF2
t.PrG01
t.PrG02
w w w
t.PrG16
Configuration parameters
Value range Description
Block auto tuning (only visible with 8800/8840
configurator!)
0
Released
1
Blocked
Block extended operating level (only visible with
8800/8840 configurator!)
0
Released
1
Blocked
Suppression error storage
0
Released
1
Blocked
OFF...9999
Password (only visible with 8800/8840 configurator!)
Block parameter level (only visible with 8800/8840
configurator!)
0
Released
1
Blocked
Block configuration level (only visible with 8800/8840
configurator!)
0
Released
1
Block
Block calibration level (only visible with 8800/8840
configurator!)
0
Released
1
Blocked
Display 3 controller operating level (only visible with
8800/8840 configurator!)
0
No value / only text
1
Display of value
2
Output value as bargraph
3
Control deviation as bargraph
4
Process value as bargraph
2...60
Display 3 display alternation time [s] (only visible with
8800/8840 configurator!)
display 3 programmer-operating level
0
Segm.-No., Segm.-Type, Progr.-remaining time
Segm.-No., Segm.-Type, Segm.-remaining time
1
Segm.-No., Segm.-Type, net-time
2
Segm.-No., Segm.-Type, Progr.-remaining time
3
Segm.-No., Segm.-Type, Segm.-remaining time
4
Segm.-No., Segm.-Type, net-time
5
8 characters
Text display 3
8 characters
Text Inf.1
8 characters
Text Inf.2
8 characters
Text Program 1
8 characters
Text Program 2
8 characters
Text Program16
46
8800 process controller
Default
0
0
0
OFF
0
0
0
2
10
0

Advertisement

Table of Contents
loading

Table of Contents