Out. 3
Name
Value range Description
O. t YP
O. A ct
Y. 1
Y. 2
Lim. 1
Lim. 2
Lim. 3
dAc. A
LP. A L
HC. A L
HC. S C
8800 process controller
Signal type selection OUT3
0
relay / logic (only visible with current/logic voltage)
1
0 ... 20 mA continuous (only visible with
current/logic/voltage)
2
4 ... 20 mA continuous (only visible with
current/logic/voltage)
3
0...10 V continuous (only visible with current/logic/voltage)
4
2...10 V continuous (only visible with current/logic/voltage)
5
transmitter supply (only visible without OPTION)
Method of operation of output OUT3 (only visible when
O.TYP=0)
0
direct / normally open
1
inverse / normally closed
Controller output Y1 (only visible when O.TYP=0)
0
not active
1
active
Controller output Y2 (only visible when O.TYP=0)
0
not active
1
active
Limit 1 signal (only visible when O.TYP=0)
0
not active
1
active
Limit 2 signal (only visible when O.TYP=0)
0
not active
1
active
Limit 3 signal (only visible when O.TYP=0)
0
not active
1
active
Valve monitoring (DAC) (only visible when O.TYP=0)
0
not active
1
active
Interruption alarm signal (LOOP) (only visible when
O.TYP=0)
0
not active
1
active
Heating current alarm signal (only visible when O.TYP=0)
0
not active
1
active
Solid state relay (SSR) short circuit signal (only visible
when O.TYP=0)
0
not active
1
active
39
Configuration level
Configuration parameters
Default
0
1
0
0
1
0
0
0
0
0
0