After the expiration of the aforementioned 5 seconds within which you should
have at least made the choice of a particular discharge mode as well as the
input of a delayed start, it starts an automatic battery test.
If no battery is connected, or an improper battery is detected, after completion
of the battery test it will be shown an appropriate error message, see „Alert
messages" on page 48.
NiCd and NiMH batteries charge process starts as described below by way of
example for a lithium battery after about 5 seconds. For lithium batteries and
PB after few seconds the battery test, it is carried out a review of the number
of cells connected batteries.
For lithium batteries and PB after few seconds the battery test, it is
carried out a review of the number of cells connected batteries. Is the
battery to charge connected not only with the charger, but also with a
balancer to the charger, the cell count is determined by the balancer and the
outcome of the review appears as shown on the left example.
For lithium batteries and PB after few seconds the battery test, it is
carried out a review of the number of cells connected batteries.
Is the battery to charge connected without a balancer to the charger,
the cell count is based on the settings manually input and the outcome of the
review appears as shown on the left example.
If the displayed number of cells matches the actual number of cells of the con-
nected battery, wait until after about 5 seconds - as described below - charge
will start automatically.
If the displayed number of cells, however, is NOT matching the actual
number of cells of the battery connected, then stop the automatic
timing by pressing the INC or DEC key and then adjust the number of
cells with one of these buttons accordingly. As an indication of the manual
intervention the color of the header information when prompted changes be-
tween red and blue.
ATTENTION!
As a result of incorrectly set number of cells or even a value too
far from cell voltages due to the balancer port, battery can ex-
plode and / or burn!
Press the ENTER button on the bottom right to start the discharge process.
26
After the lapse of the aforementioned 5 seconds or if necessary, after a manu-
al start, discharge process is begun. Otherwise, an error message is shown.
Note:
Tap the image to go directly to the „data display", see page 35.
1 Discharge mode
2 Actual discharge time
3 Battery temperature (Only with sensor)
4 Discharged capacity
5 Actual discharging voltage
6 Actual discharge current
7 Actual voltage of the power supply
8 Internal resistance of the battery
9 Vc = Voltage center (the center line voltage value actually assigned)
Vr = Voltage range (vertical range of the voltage display)
10 History of the discharging voltage
To change the actual discharge current tap the display to the actual discharge
current (6). In the lower half of the display appears a selection window.
Increase or decrease now by using the INC / DEC buttons to select the current
value, such as 1.80 A. If necessary, you can also specify a value that strongly
deviate from the current value by touching one of the six option buttons.
Tapping the
field closes the window and takes the selected value into the
memory.