Measurements
Electrical outlet location
1
4"
22 ¹⁄₈"
opening
Allow ¾"
overlap.
23 ½"
min depth
36"
counter-
top
height
24"
cabinet min.
2
4 ¹¹⁄₁₆"
1 ²³⁄₃₂"
15 ⁵⁄₈ "
DRAWERMICRO OVEN MEASUREMENTS: Figures 1 and 2
contain many DrawerMicro Oven measurements for reference
when planning the drawer's location which can be installed
below any electric or gas wall oven. It can also be installed
using an electrical outlet in an adjacent cabinet within the
area where the provided electrical cord can reach. Power cord
access hole in cabinet should be a minimum 1½" diameter hole
and deburred of all sharp edges.
IMPORTANT: Always allow sufficient power cord length to the
electrical outlet to prevent tension.
DO NOT USE AN EXTENSION CORD. If the power supply cord
is too short, have a qualified electrician or serviceman install
an outlet near the appliance.
Always check electrical codes for requirements.
(6")
Anti-Tip
block
3 ¹⁄₂"
5"
14 ¹³ ₁₆"
to bottom
Allow ³ ₈"
of Anti-Tip
overlap
block
14 ¹³ ₁₆"
opening
Allow ¾"
overlap.
Allow
Floor must
support
⁷ ₁₆"
overlap
100 lbs.
Approximately
19"or less
(recommended)
21 ¹⁹⁄₃₂"
14 ¹⁹⁄₃₂"
15"
auto drawer
opening
23 ³⁄₈"
1 ³⁄₄"
door thickness
23 ⁷⁄₈"

Clearances and Dimensions

• Dimensions that are shown in figure 1 must
be used. Given dimensions provide minimum
clearance. Locate electrical outlet in the shaded
area in the upper left-hand corner of the cutout.
See figure 4.
• Contact surface must be solid and level. Pay
special attention to the floor on which the
appliance will sit. The floor of the opening should
be constructed of plywood strong enough to
support the weight of the oven (about 100
pounds).
• Check location where the DrawerMicro Oven will
be installed for proper electrical supply.
• Your appliance can be built into a cabinet or wall
by itself or under a gas or electric wall oven.
• Be sure that the clearance of the floor between
the wall oven and the DrawerMicro Oven is a
minimum of 2".
• The microwave interior will easily accommodate
a 9" x 13" oblong dish or a bag of microwave
popcorn.

Anti-Tip Block

NORMAL INSTALLATION STEPS
Anti-Tip Block Installation Instructions
• To reduce the risk of tipping of the drawer, the
Anti-Tip block must be properly installed located
14-13/16" above the floor on which the appliance
will sit. The 6" Anti-Tip block must be provided
by the installer. See figure 1. The Anti-Tip block
prevents serious injury that might result from
spilled hot liquids.