f.
Remove all electrical connectors,
including the thermistor.
g.
Pull out the heat exchanger unit
towards yourself.
13) Removal of Thermal Fuse
CAUTION
- 240 volt potential exposure. Isolate the
appliance and reconfirm with a neon
screwdriver or multimeter.
h.
Remove the heat exchanger unit;
refer to section 10.
Infinity REU-2425W
i.
Disconnect and remove the thermal
fuse (phillips head).
* Fit the fuse as shown below
- 50 -
Issue 2 - 5/07/04 ©Rinnai