Rinnai REU-2018W Service Manual page 38

Compact continuous flow gas hot water system
Table of Contents

Advertisement

9) Is main gas solenoid valve (SV
10) Is the change over solenoid (SV
11) Is the change over solenoid valve (SV
Infinity REU-2425W
) normal?
1
If error "11" is displayed, check the main gas
solenoid valve.
p.
# Disconnect the main gas solenoid
valve (SV
the resistance at the solenoid
terminals. Normal: 0.9 ~ 1.3 k
If normal, check (q) below.
Faulty: Replace the main gas solenoid
valve.
q.
Measure voltage main gas solenoid
valve (SV
Normal: DC80~100V
If normal, proceed to check item 7)
below.
Faulty: Replace the PCB unit.
) operating normally?
2
If error "11" is displayed, check the change
over solenoid valve (SV
r.
# Disconnect the main gas solenoid
valve (SV
the resistance at the solenoid
terminals.
Normal: 1.3 ~ 1.9 k
If normal, check (s) below.
Faulty:
solenoid valve (SV
s.
Measure voltage at change over
solenoid valve (SV
connector.
Normal: DC 80 ~ 100V
If normal, check item 8) below.
Faulty: Replace the PCB unit
) normal?
3
t.
# Disconnect the change over
solenoid valve (SV
measure the resistance at the
solenoid terminals.
Normal: 1.3 ~ 1.9 k
If normal, check (u) below.
Faulty:
solenoid valve (SV
u.
Measure the voltage at changeover
solenoid valve (SV
connector.
Normal: DC 80 ~ 100V
If normal, check item 9).
Faulty: Replace the PCB unit.
- 35 -
), connector and measure
1
) pink ~ black connector.
2
).
2
) connector, and measure
2
.
Replace
the
change
).
2
) blue ~ black
3
) connector, and
3
Replace
the
change
).
3
) blue ~ black
3
Issue 2 - 5/07/04 ©Rinnai
over
over