Refer to diagram on bottom of previous page.
3) Is the remote control normal?
No combustion (despite remote control indication)
4) Is the water flow sensor normal?
Infinity REU-2425W
e.
Check the voltage at centre PCB
connector F, green~green.
Normal: AC 16 ~ 20V
If normal, check item 3) below.
Faulty: Replace the transformer.
Note: Transformer voltage above applies
to the appliance in a standby, non-
functioning state.
Check voltage between the two remote
control cable conductors.
f.
Check the voltage between terminals
on the remote control terminal mount
(H
).
1
Normal: DC 10 ~ 13V
If normal, check for open circuit or shorts
before replacing the remote control.
Faulty: Replace PCB.
g.
Measure the voltage between red
and black of the relay connector (a
Normal: DC 11 ~ 13V
If normal, go to (h).
Faulty: Replace water flow control.
h.
Measure the voltage between yellow
and black of the relay connector (a
Normal: DC 2 ~ 10V
If normal, go to 2).
Faulty: Replace the water flow sensor.
- 32 -
).