Performance Data - Electra WNG 9 DCI INV Technical Manual

Multi split trio quattro dci
Table of Contents

Advertisement

5.

PERFORMANCE DATA

5.1
Outdoor Unit Trio DCI Combinations (Based on WNG)
5.1.1
Cooling
Model
A
9
25
-
12
35
-
18
50
-
9+9
25+25
-
9+12
25+35
-
9+18
25+50
-
12+12
35+35
-
12+18
35+35
-
9+9+9
25+25+25
2.40
9+9+12
25+25+35
2.20
9+9+18
25+25+50
1.83
9+12+12
25+35+35
1.99
9+12+18
25+35+50
1.69
12+12+12
35+35+35
2.44
12+12+18
35+35+50
2.09
Nominal Indoor Units Combination
Cooling Capacity [KW]
B
C
Nom.
Min.
-
2.50
2.50
1.30
-
3.50
3.50
1.30
-
5.00
5.00
1.49
2.54
2.54
5.08
1.86
2.57
3.42
5.99
1.86
2.44
4.88
7.32
1.86
3.46
3.46
6.92
1.86
2.93
4.39
7.32
1.86
2.40
2.40
7.20
2.69
2.20
2.93
7.33
2.69
1.83
3.66
7.32
2.69
2.66
2.66
7.31
2.69
2.25
3.37
7.31
2.69
2.44
2.44
7.32
2.69
2.09
3.13
7.30
2.69
Revision 0
Power Consumption [W]
Max.
Nom.
Min.
3.70
685
500
4.40
968
500
5.93
1,393
566
6.56
1,498
683
7.73
1,783
683
9.00
2,203
659
9.00
2,075
683
9.00
2,203
659
8.98
2,240
949
9.00
2,281
949
9.00
2,278
962
9.00
2,275
949
9.00
2,275
962
9.00
2,278
990
9.00
2,272
962
PERFORMANCE DATA
Energy
COP
Efficiency
Nom.
Class
Max.
1,025
3.65
A
1,223
3.62
A
1,656
3.59
A
1,856
3.39
A
2,541
3.36
A
3,046
3.32
A
2,246
3.33
A
3,055
3.32
A
3,049
3.21
A
3,157
3.21
A
3,097
3.21
A
3,097
3.21
A
3,061
3.21
A
3,085
3.21
A
3,086
3.21
A
5-1

Hide quick links: