12.1.9. Water Temperature Thermo Shift Setting
• Switchs are ignored during "PUMPDW" = ON.
• Switchs are ignored during "STATUS" = ON.
• "
", "
", "SELECT" switch are ignored if "SETTING" = OFF.
• "CANCEL" switch is ignored if "SETTING" = OFF & "STATUS" = OFF.
• If "SET" Switch pressed for less than 5secs, immediately enter water temperature shift setting mode.
• Once enter this setting mode, "SETTING" display is ON.
This setting mode is used to easily shift the target water outlet temperature.
12.1.10. Fan Motor Operation
Fan motor is adjusted according to operation condition. It starts when compressor starts operation and it stops 30 seconds after
compressor stops operation.