Heating Capacity Table - Panasonic WH-MDC09C3E5 Servise Manual

Monobloc air-to-water heatpump system
Hide thumbs Also See for WH-MDC09C3E5:
Table of Contents

Advertisement

18.2. Heating Capacity Table

18.2.1. WH-MDC09C3E5
LWC
Tamb
HC
-15
8.65
-7
9.35
2
9.31
7
9.00
25
9.00
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
18.2.2. WH-MDC12C6E5
LWC
Tamb
HC
-15
9.30
-7
10.40
2
11.80
7
12.00
25
12.00
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
18.2.3. WH-MDC14C6E5
LWC
Tamb
HC
-15
9.90
-7
11.10
2
12.90
7
14.00
25
14.00
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
30
35
IP
HC
IP
3.10
8.30
3.25
2.95
9.00
3.20
2.39
9.00
2.55
1.58
9.00
1.90
1.09
9.00
1.28
30
35
IP
HC
IP
3.50
8.90
3.66
3.41
10.00
3.70
3.14
11.40
3.34
2.14
12.00
2.57
1.42
12.00
1.70
30
35
IP
HC
IP
3.91
9.50
4.05
3.73
10.70
4.00
3.51
12.40
3.73
2.60
14.00
3.11
1.75
14.00
2.10
40
45
HC
IP
HC
7.95
3.45
7.60
8.85
3.50
8.70
9.00
2.82
9.00
9.00
2.20
9.00
8.73
1.48
8.46
40
45
HC
IP
HC
8.50
3.83
8.10
9.60
3.90
9.20
11.00
3.57
10.60
12.00
3.00
12.00
11.80
1.98
11.70
40
45
HC
IP
HC
9.00
4.19
8.60
10.20
4.20
9.80
11.90
3.95
11.40
14.00
3.63
14.00
14.00
2.45
14.00
127
50
IP
HC
IP
3.65
7.15
3.75
3.80
8.30
3.85
3.09
8.90
3.53
2.50
9.00
2.80
1.68
8.28
1.86
50
IP
HC
IP
3.99
7.50
4.09
4.10
8.70
4.20
3.78
9.80
3.98
3.43
12.00
3.82
2.27
11.50
2.53
50
IP
HC
IP
4.33
7.90
4.45
4.40
9.10
4.57
4.17
10.40
4.29
4.14
13.60
4.61
2.80
14.00
3.05
55
HC
IP
6.70
3.85
7.90
3.90
8.80
3.98
9.00
3.10
8.10
2.04
55
HC
IP
7.00
4.20
8.20
4.31
9.10
4.18
12.00
4.20
11.40
2.78
55
HC
IP
7.30
4.56
8.50
4.74
9.50
4.40
13.30
5.08
14.00
3.44

Hide quick links: