18.2. Heating Capacity Table
18.2.1. WH-MDC09C3E5
LWC
Tamb
HC
-15
8.65
-7
9.35
2
9.31
7
9.00
25
9.00
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
18.2.2. WH-MDC12C6E5
LWC
Tamb
HC
-15
9.30
-7
10.40
2
11.80
7
12.00
25
12.00
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
18.2.3. WH-MDC14C6E5
LWC
Tamb
HC
-15
9.90
-7
11.10
2
12.90
7
14.00
25
14.00
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
30
35
IP
HC
IP
3.10
8.30
3.25
2.95
9.00
3.20
2.39
9.00
2.55
1.58
9.00
1.90
1.09
9.00
1.28
30
35
IP
HC
IP
3.50
8.90
3.66
3.41
10.00
3.70
3.14
11.40
3.34
2.14
12.00
2.57
1.42
12.00
1.70
30
35
IP
HC
IP
3.91
9.50
4.05
3.73
10.70
4.00
3.51
12.40
3.73
2.60
14.00
3.11
1.75
14.00
2.10
40
45
HC
IP
HC
7.95
3.45
7.60
8.85
3.50
8.70
9.00
2.82
9.00
9.00
2.20
9.00
8.73
1.48
8.46
40
45
HC
IP
HC
8.50
3.83
8.10
9.60
3.90
9.20
11.00
3.57
10.60
12.00
3.00
12.00
11.80
1.98
11.70
40
45
HC
IP
HC
9.00
4.19
8.60
10.20
4.20
9.80
11.90
3.95
11.40
14.00
3.63
14.00
14.00
2.45
14.00
127
50
IP
HC
IP
3.65
7.15
3.75
3.80
8.30
3.85
3.09
8.90
3.53
2.50
9.00
2.80
1.68
8.28
1.86
50
IP
HC
IP
3.99
7.50
4.09
4.10
8.70
4.20
3.78
9.80
3.98
3.43
12.00
3.82
2.27
11.50
2.53
50
IP
HC
IP
4.33
7.90
4.45
4.40
9.10
4.57
4.17
10.40
4.29
4.14
13.60
4.61
2.80
14.00
3.05
55
HC
IP
6.70
3.85
7.90
3.90
8.80
3.98
9.00
3.10
8.10
2.04
55
HC
IP
7.00
4.20
8.20
4.31
9.10
4.18
12.00
4.20
11.40
2.78
55
HC
IP
7.30
4.56
8.50
4.74
9.50
4.40
13.30
5.08
14.00
3.44