Servicing The Fuses - Toro Z MASTER G3 Operator's Manual

152cm turbo force side discharge mower
Hide thumbs Also See for Z MASTER G3:
Table of Contents

Advertisement

Charging the Battery
Charging the battery produces gasses that can
explode.
Never smoke near the battery and keep sparks
and flames away from battery.
Important: Always keep the battery fully charged
(1.265 specific gravity). This is especially important
to prevent battery damage when the temperature is
below 32°F (0°C).
1. Charge battery for 10 to 15 minutes at 25 to 30 amps
or 30 minutes at 10 amps.
2. When the battery is fully charged, unplug the charger
from the electrical outlet, then disconnect the
charger leads from the battery posts (Figure 58).
3. Install the battery in the machine and connect the
battery cables, refer to Installing the Battery.
Note: Do not run the machine with the battery
disconnected, electrical damage may occur.
Figure 58
1. Positive Battery Post
2. Negative Battery Post
3. Red (+) Charger Lead
4. Black (-) Charger Lead

Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance, however, if a fuse blows check the
component/circuit for a malfunction or short.
1. The fuses are located on right hand console next to
the seat (Figure 59).
2. To replace the fuses, pull out on the fuse to remove
it.
3. Install a new fuse (Figure 59).
1. Optional accesory-15 amp 4. Main-25amp
2. Charge-25amp
3. PTO-10amp
43
Figure 59
5. Console