HYDROSTATIC DRIVE SYSTEM
Tracking Adjustment
Note: Do not make tracking adjustments on cold
hydrostatic drive systems. Safely warm the
drive system before making adjustments.
- Adjust the eccentric on the LEFT side if the unit
pulls to the RIGHT
- Adjust the eccentric on the RIGHT side in the unit
pulls to the LEFT.
1. Remove the (1) bolt that secures the control panel
cover to access the adjustment eccentric (Fig. 068).
(RH side shown)
5
5-6
Fig. 068
PICT-2040
2. Hold the pivot bolt in position with a 1/4" hex wrench,
and then slightly loosen the eccentric pivot nut (A)
(Fig. 069).
Fig. 069
3. Use a 1/4" hex wrench to adjust the eccentric pivot
bolt until the unit tracks straight (Fig. 070).
Fig. 070
4. After proper tracking has been achieved, hold
the pivot bolt in position with a 1/4" hex wrench,
and then torque the eccentric pivot nut (A) to
specification – 8 ft-lbs. (11 Nm).
5. Install the control panel cover, then torque the
retaining bolt to specification – 4.5 ft-lbs. (6 Nm).
6. Verify proper drive system function.