REPLACING THE POWER SUPPLY CABLE
Important! This appliance must be connected to the electricity supply only by an
authorised person.
To connect the supply cable:
■
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig. 2).
■
Open the cable gland by unscrewing screw "F" (fig. 3), unscrew the terminal screws and
remove the cable.
■
The new supply cable, of suitable type and section, is connected to the terminal board
following the diagram of fig. 1.
N.B. The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
220-240 V ac
FEEDER CABLE SECTION
TYPE H05RR-F
3 x 2,5 mm
2
(**)
(**) Connection with wall box connection.
Figure 2
4400 W (19.13 A)
A
Figure 1
220 - 240 V ac
N (L
L
1
E
Figure 3
F
)
2