REPLACING THE POWER SUPPLY CABLE
Important! This appliance must be connected to the electricity supply only by an
authorised person.
To connect the supply cable:
■
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
5).
■
Unscrew the screw "D" and open completely the cable clamp "E" (fig. 6).
■
Connect the phase, neutral and earth wires to terminal board "G" according to the
diagram in fig. 7.
■
Strain the feeder cable and block it with cable clamp "E" (by screwing screw "D").
■
Close the terminal block cover (check the two hooks "A" are correctly hooked).
N.B. The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
220-240 V ac
FEEDER CABLE SECTION
TYPE H05RR-F
3 x 1,5 mm
(*) (**)
2
(*) Connection possible with plug and outlet
(**) Connection with wall box connection.
Figure 6
G
L1
12
3050 W (13.26 A)
E
PE
N
L2
Figure 5
Figure 7
220-240 V ac
L
N
PE
A