Replacing The Power Supply Cable - DeLonghi DEP7410P Installation And Service Instructions Manual

Multifunction pyrolytic oven
Table of Contents

Advertisement

REPLACING THE POWER SUPPLY CABLE

Important! This appliance must be connected to the electricity supply only by an
authorised person.
To connect the supply cable:
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
5).
Unscrew the screw "D" and open completely the cable clamp "E" (fig. 6).
Connect the phase, neutral and earth wires to terminal board "G" according to the
diagram in fig. 7.
Strain the feeder cable and block it with cable clamp "E" (by screwing screw "D").
Close the terminal block cover (check the two hooks "A" are correctly hooked).
N.B. The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
220-240 V ac
FEEDER CABLE SECTION
TYPE H05RR-F
3 x 1,5 mm
(*) (**)
2
(*) Connection possible with plug and outlet
(**) Connection with wall box connection.
Figure 6
G
L1
12
3050 W (13.26 A)
E
PE
N
L2
Figure 5
Figure 7
220-240 V ac
L
N
PE
A

Advertisement