SINGLE -PERSON LIFT COULD
USE ASSISTANCE WHEN MOVING
IMPORTANT: Installation of Refractory panels should
be done after the fireplace is placed in a permanent
location.
1. Remove grate, screen assemblies and all hardware components
out of the firebox. The bottom panel is preinstalled in the firebox.
Make sure the bottom refractory panels is centered in the firebox
and flush with the front of the fireplace.
2. Place cardboard on top of bottom refactory panel as a protection
to prevent shipping and scratching during installation of the other
panels.
3. Position "Z" shaped grate retaining brackets on top of the notched
area toward the rear of the bottom refractory. They should be
postioned a distance apart as shown in Figure 21.
4. Install rear refractory panel. This panel has a top and bottom. To
determine which is which, match up the pattern on the rear panel
with the left and right sides before installing the rear panel. Make
sure panel is center before continuing.
5. Install the right and left refractory panels with the gas line knock-
outs orientated down toward the bottom refractory. Align the left
and right panels with the rear panel so the grout lines line up.
6. Install the upper corner brackets and tighten set screws (Figure
22).
7. Install grate by placing rear legs into slots in the grate retainers
(Figure 22).
WARNING: Risk of fire! Replace grate with IN-
NOVATIVE HEARTH PRODUCTS grate only (see Parts,
page 19). This grate has been designed to keep the
operation of your fireplace safe and efficient.
INSTALLING SCREEN
1. Slide round end of screen rod into rings at top of screen. Attach one
push-on nut to end of rod before attaching last ring of screen.
2. Insert the round end screen rod into hole on the left and right side
of smoke shelf (Figure 23).
3. Mount flat end of screen rod with #10 x 5/8" to center of smoke
shelf.
4. Install other screen rod in same manner.
14
REFRACTORY PANEL INSTALLATION
WARNING
LIFTING HAZARD
CAUSE INJURY.
OR LIFTING.
Superiorfireplaces.US.com
Figure 21 - Installing Grate Retainers
LEFT BRICK
PANEL
GRATE
Figure 22 - Installing Refractory Panels
Rating Plate
Figure 23 - Installing Fireplace Screen
UPPER CORNER
BRACKET (2x)
REAR BRICK
PANEL
GRATE RETAINER
BRACKET (2x)
RIGHT BRICK
PANEL
BOTTOM
BRICK PANEL
ASH PANEL
Hole for Screen Rod
Leading
Bricks
126601-01B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents