Replace Fuel Filter; Storage - Generac Power Systems iX series Owner's Manual

Digital inverter portable generator
Hide thumbs Also See for iX series:
Table of Contents

Advertisement

Available languages

Available languages

Inspect muffler for cracks, corrosion, or other
damage. Remove spark arrester, if equipped,
inspect for damage or carbon blockage.
Replace parts as required.
Inspect Spark Arrester Screen (50
State)
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces
could result in severe burns or fire.
1. Remove clamp (A) and screen retainer
(B). See
Figure
2. Slide spark arrestor screens (C) out from
muffler outlet (D).
3. Inspect screens and replace if torn, perfo-
rated or otherwise damaged. Do NOT use
a defective screen. If screens are not dam-
aged, clean with commercial solvent.
4. Replace screens (C) and retainer (B) and
secure with clamp (A).
D
B
A
C
Figure 4-4. Spark Arrestor Screen

Replace Fuel Filter

Explosion and Fire. Fuel and vapors are
extremely flammable and explosive. Keep fire
and spark away. Failure to do so will result
in death or serious injury.
Locate fuel filter just below engine intake
housing. See
Figure
off is OFF (O).
1. Remove the pinch clamps from fuel filter
(A) and pull hoses free.
2. Replace used filter.
3. Push fuel hoses onto barbed filter fittings
until they seat completely.
4. Replace clamps making sure they are
seated on the fittings.
Owner's Manual for Portable Generator
WARNING
4-4.
DANGER
4-5. Make sure fuel shut-
A
(000108)

Storage

General
It is recommended to start and run the genera-
tor for 30 minutes, every 30 days. If this is not
possible, refer to the following list to prepare
unit for storage.
• DO NOT place a storage cover on a hot
000735
generator. Allow unit to cool to room tem-
perature before storage.
• DO NOT store fuel from one season to
another unless properly treated.
• Replace fuel container if rust is present.
Rust in fuel will cause fuel system prob-
lems.
• Cover unit with a suitable protective, mois-
ture resistant cover.
(000168)
• Store unit in a clean and dry area.
• Always store generator and fuel away from
heat and ignition sources.
Figure 4-5. Replace Fuel Filter
DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Store fuel in a well
ventilated area. Keep fire and spark away. Failure
to do so will result in death or serious injury.
WARNING
Risk of Fire. Verify machine has properly
cooled before installing cover and storing
machine. Hot surfaces could result in fire.
000732
(000143)
(000109)
13