Replacing The Vdu And Vdu Resistor; Replacing The Psu; Replacing The Igd - Siemens simovert master drive Operating Instructions Manual

Types j to m dc-ac
Table of Contents

Advertisement

Maintenance
5.2.7.2

Replacing the VDU and VDU resistor

VDU Voltage-Dividing Unit
VDU and VDU resistor are only available for drive converters with higher supply voltages. The VDU mounting
bracket is part of the electronic module assembly.
♦ VDU
• Remove the plug connectors
• Release the mounting bolt
• Remove the VDU
Install the new VDU in the inverse sequence.
♦ VDU resistor
• Release the cable ties
• Remove the plug connections
• Unbolt the VDU resistor
Install the new VDU resistor in the inverse sequence
5.2.7.3

Replacing the PSU

PSU Power-Supply Unit (Power Supply)
♦ Remove the VDU and VDU resistor (if available)
♦ Remove the VDU mounting panel
♦ Release the plug connections on the PSU
♦ Release the bolts ( six Torx M4) on the PSU
♦ Remove the PSU
Install the new PSU in the inverse sequence
5.2.7.4

Replacing the IGD

IGD
IGBT-Gate Drive
The IGD is located behind the module busbars and consists of
• Remove the capacitors
• Remove SML and SMU
• Remove the module busing
♦ Type of construction J
• Remove nine fiber-optic cables at the top of the
IGD
• Release the mounting bolts and remove the
IGD.
Install a new IGD in the reverse sequence.
5-6
one board for type of construction J
three boards for type of construction K
♦ Type of construction K
• Remove the fiber-optic cables at the left of the
IGD (three per IGD)
• Remove the P15 cable
• Release the mounting bolts
• Withdraw the IGD from the retaining bolts
towards the right and remove
• Insert a new IGD, and insert towards the left in
the groove of the mounting bolts under the
incoming busbars.
SIMOVERT MASTER DRIVES
12.96
Siemens AG
6SE7087-6BM70
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents