Sony DVP-S715 Service Manual page 75

Hide thumbs Also See for DVP-S715:
Table of Contents

Advertisement

How to see Emergency History
1
2
1 EMG CODE
2 MECHA MODE
3 DISC TYPE (Mecha Mode: 6π)
1 EMG CODE (Emergency code list)
Digital Pass
01:
EEPROM Read NG
02:
EEPROM Write NG
03:
EEPROM Busy Time Out
04:
Emergency History Pointer NG
06:
HICON SYSCON Communication NG
07:
HICON V-sync NG
Electrical Adjustment
10:
EEPROM Check NG
16:
DSP Check NG
Mecha
20:
Home Position Time Out
21:
Sled Driver NG
26:
Tray NG
27:
Roulette NG
Tilt/Adaptation
30:
Hy Det Level NG
31:
Sled Offset Cancel NG
32:
Focus Gain NG
33:
Tracking Offset NG
34:
Tracking Gain NG
35:
Jitter NG
Focus
40:
Focus Servo Lock NG
41:
Focus Jump NG
Spindle
60:
Miss Chuck
61:
Spindle Lock Time Out
62:
Spindle Reckless
63:
CLV Lock NG
64:
CLV Lock Time Out
65:
CAV Speed NG
Spindle Speed × 1 NG
66:
Seek System
70:
Req Address NG
71:
Req Time Code NG
72:
Req Track No. NG
73:
Seek NG
Data Relation
80:
Address Continuity NG
81:
Address Read NG
82:
TOC Read Time Out
83 – 87:
Physical Information Read Error
88:
Layer No. NG
89:
CD Text Data Read Error
Etc
3
Syscon
Hicon
Power system
Drvcon
2 MECHA MODE (Mecha mode list)
6-18
90:
Recovery NG
96:
Auto Sequence Time Out
97:
Auto Sequence Fail
A0:
Stop request from drive controller was received
A1:
At the mode change command, the mode could
not be changed within specified time and the
drive stopped.
A2:
Retry due to supply error failed and the drive
stopped.
A3:
Disc directory configuration and information file
are illegal and the drive stopped.
A4:
The drive stopped as a DVD-R disc was used.
A5:
Coded data could not be decoded and the drive
stooped.
A6:
At slow R, the destination of reverse search is
illegal and the drive stopped.
A7:
Supply error and stopped.
B0:
SYSCON error was due to supply system.
B1:
SYSCON error was due to VIDEO hung up
B2:
DMX error
B3:
At slow R, data supply time out
B4:
At slow R, wrong Navi Pack sector address
B5:
At slow R, VIDEO hung up
B6:
At slow R, Gttgt end time out
B7:
At FF/FR, data supply time out
B8:
At FF/FR, VIDEO hung up
C0:
HICON ROM destination is wrong
C1:
HICON UART1 communication port NG
D0:
The power turned off because of power off re-
quest from drive controller.
D1:
The mode change to Stop mode failed and the
power turned off.
E0:
DRVCON system error
E1:
DRVCON system error
00:
Power ON Ready
10:
Stop
20:
Trace (data supply mode)
30:
Pause
40:
Drvcon Initialize
50:
Mecha Initialize
6π:
Spin Up
61:
Adaptation (Tracking Offset)
62:
Adaptation (Jitter/Gain)
63:
TOC/Control Data Read
60:
Etc
70:
Spin Down
80:
Seek
90:
Error Recovery

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents