Electrical Connections - Vivax ACP-18COFM50GEI User Manual

Hide thumbs Also See for ACP-18COFM50GEI:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 64

ELECTRICAL CONNECTIONS

ACP-18COFM50GEI
1.R emove the handle at the right side plate of the
outdoor unit (one screw).
.
2
Remove the cable clamp, connect the power connection
cable with the terminal at the row of connection and fix
the connection. The fitting line distributing must be
consistent with the indoor unit. terminal of line bank.
Wiring should meet that of indoor unit.
3.
Fix power connection wire by wire clamp.
4.
Ensure wire has been fixed well.
5.
Install the handle.
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of some
electric components.After fixing cable, ensure that
leads between connection to fixed point have some space.
The connection pipes and the connectiong wirings of
the unit A and unit B must be corresponding to each
other respective.
The appliance shall be installed in accordance with
national wiring regulations.
4
To unit A
To unit B
Blue
YEGN
Blue
Black
Brown
Black
Power
connecting
cord
INSTALLER
Handle
YEGN
YEGN
Blue
Brown
Brown
Power
connecting
cord
To the power supply
N
L

Advertisement