Abl Operation Level Adjustment - Panasonic TH-65PX600U Service Manual

Digital high definition plasma television
Hide thumbs Also See for TH-65PX600U:
Table of Contents

Advertisement

12.3. ABL operation level adjustment

Instrument Name
· PC (RGB) signal generator
(Leader: VGA/No.9 signal)
· Wattmeter
[condition]
· Make sure the set is aged for 30 minutes or more before adjustment.
· Voltage 120V 50/60Hz (variation within 1%)
· Volume at minimum and screen size at full
· Component 1 input, Pic. mode : Vivid (Normal : Set)
1. Connect the set's AC power to the wattmeter.
2. Receive the VGA No.9 signal from Leader.
3. Select the PWRCTRL item in WB-ADJ in the factory mode (INTERCAT2001).
4. Adjust PWRCTRL so the set's power consumption are as follows.
Adjust to shift large to small for DAC.
Factory adjustment with OSD
TH-65PX600U 695 ± 8W
Connection
· Component 1
· Connect
the
adjustment set to the wattmeter.
Procedure
43
AC
power
of
the
No.9 Signal
Top half: Full color bar
Bottom half: Horizontal 10 steps bar
Notes:
1. It is OK that falling down the power
few watts when exiting the factory
adjustment mode.
2. Adjust the large number for DAC
when they have 2 adjustment
points.
TH-65PX600U
Remarks
Remarks

Hide quick links: