This function should not be enabled if the PTZ/ePTZ function of the camera is being used.
This function can only be configured if MS Internet Explorer is used as a browser (ActiveX mode).

9.3 Exposure Settings

With this function you can set specified exposure settings
from the CMOS-Sensor of the camera.
„Exposure level" Sets the default value of the aperture.
The higher the value the brighter the picture.
„Measurement window":
„Full view"
The camera takes the overall video image as reference for
exposure settings.
„Custom"
You can add manually customized windows as inclusive
or exclusive regions. The camera uses this windows as
reference for exposure settings.
„Add inclusive window"
The camera inludes this window for exposure settings.
To change the format of window simply modify it with the
mouse.
„Add exclusive window"
The camera ignores this window for exposure settings.
To change the format of window simply modify it with the
mouse.
„BLC"
A predefined window will be used for exposure settings.
Back light compensation improves the recognition of objects in front of ligth sources.
„Exposure time"
The shorter the time is set, the less light will be applied to the sensor and the image becomes darker. The
picture sharpness during fast movements decreases because of longer exposure time.
You can either define an area in which the camera automatically adjust the exposure time or fix the value.To
set the zone please use the mouse.
„Gain control"
In low light conditions more image details can be shown. Depending on the configured value, a better image
quality in a dark room can be achieved.
You can either define an area in which the camera automatically adjusts the gain or fix the value.
To set the zone please use the mouse.