Condenser
Models
Tube Material
Outer Diameter
Thickness
Row
No. of Tubes/Row
Fin Material
Thickness
Fin Pitch
Fin Surface
Total Face Area
Fan
Type
No.of /Unit
Fan Motor
Starting Method
Rated Output
Poles
Phase
Insulation Class
Heat pump model
Cooling only model
mm
mm
mm
No./inch
2
m
kW
32
CU-W50BBP8
CU-V50BBP8
Copper tube
9.52
0.3
2
46
Aluminum
0.105
14
X-Louvre-fin
1.05
Propeller Fan
2
Direct on-line Starting
0.055 X 2
6
Single-Phase
E

Advertisement