Operation; Before Operating - Toro 30607 Operator's Manual

Rotary mower
Hide thumbs Also See for 30607:
Table of Contents

Advertisement

Operation

Note: Determine the left and right sides of the machine
from the normal operating position.

Before Operating

CAUTION
If you leave the key in the ignition switch, someone
could accidently start the engine and seriously
injure you or other bystanders.
Remove the key from the ignition before you do any
maintenance.
Checking the Engine Oil
Service Interval: Before each use or daily
The engine is shipped with oil in the crankcase; however, the
oil level must be checked before and after the engine is first
started.
The crankcase capacity is 5.7 liters (6 qt.) with the filter.
Use high-quality engine oil that meets the following
specifications:
API Classification Level Required: CJ-4 or higher.
Preferred oil: SAE 15W-40 (above 0°F)
Alternate oil: SAE 10W-30 or 5W-30 (all temperatures)
Important: Using non CJ-4 or higher oil will cause
DPF plugging and damage the engine.
Toro Premium Engine Oil is available from your distributor
in either 15W-40 or 10W-30 viscosity. See the parts catalog
for part numbers.
Note: The best time to check the engine oil is when the
engine is cool before it has been started for the day. If it has
already been run, allow the oil to drain back down to the
sump for at least 10 minutes before checking. If the oil level
is at or below the "add" mark on the dipstick, add oil to bring
the oil level to the "full" mark. DO NOT OVERFILL.
If the oil level is between the "full" and "add" marks, no
additional oil is required.
1. Park the machine on a level surface. Unlock the engine
cover latches.
2. Open the engine cover.
3. Remove the dipstick, wipe it clean, install the dipstick
into the tube, and pull it out again. The oil level should
be up to the Full mark (Figure 10).
1. Dipstick
4. If the oil is below the Full mark, remove the fill cap
(Figure 10) and add oil until the level reaches the Full
mark. Do not overfill.
5. Install the oil fill cap and dipstick.
6. Close the engine cover and secure it with the latches.
Checking the Cooling System
Service Interval: Before each use or daily
Check level of coolant at the beginning of each day. Capacity
of system is 8.52 liters (9 qts) for the Groundsmaster 4000
and 20 liters (14.5 qts) for the Groundsmaster 4010.
1. Carefully remove the radiator cap and expansion tank
cap (Figure 11).
CAUTION
If the engine has been running, the
pressurized, hot coolant can escape and cause
burns.
• Do not open the radiator cap when the
engine is running.
• Use a rag when opening the radiator cap,
and open the cap slowly to allow steam to
escape.
2. Check the coolant level in the radiator. The radiator
should be filled to the top of the filler neck and the
expansion tank filled to the Full mark.
23
Figure 10
2. Oil fill cap

Advertisement

Table of Contents
loading

This manual is also suitable for:

30609Groundsmaster 4000-dGroundsmaster 4010-d