8.16. Installing the Platen Cover (DA-UC200) for PU

8.16.1. Contents
Qty.
1
Platen Cover
1
Scanning Pad
2
Platen Hinge
4
Screw
1
Installation Instructions
Note:
1. The part number(s) may differ depending on the Destination.
2. Refer to the Parts List in the Parts Manual.
8.16.2. Installation
(2)
(3)
(5) x6
Ver. 1.2
Description
(1)
(2)
(1)
(4)
Part No.
DZMA002394
DZJM000428
DZMH000013
XTB3+12JFJ
DZSM000303 This document
(1) Install 2 Platen Hinges.
(2) Secure the Platen Hinges with 2 Screws each.
(3) Install the Platen Cover.
(4) Place the Scanning Pad on the glass aligning it
with the upper left corner.
(5) Peel off 6 adhesive strip protectors from the
Scanning Pad.
(6) Close the Platen Cover.
Note:
Reopen the Platen Cover and push the
Scanning Pad gently to glue it properly.