Bypass Board Connections - SentexSystems CROWN JEWEL Installation Instructions Manual

Telephone entry system
Hide thumbs Also See for CROWN JEWEL:
Table of Contents

Advertisement

C. BYPASS BOARD CONNECTIONS
The bypass board allows the Crown Jewel to be bypassed so normal telephone operation can be
maintained in the event of a malfunction.
1. Standard Connection
1. Connect TB3 on the main processor board to the SYSTEM area of the bypass board as shown in
Figures 5 and 6.
2. Connect one set of the 18 to 24 AWG twisted pair telephone wires between the telephone line
and the Bypass Board TELCO area as follows:
a.
On the Bypass Board TELCO area, connect the red wire to the tip terminal (marked as "T"),
and the green wire to the ring terminal (marked as "R").
b.
Connect the opposite ends of these wires to the incoming telephone line.
3. Connect the other set of twisted pair telephone wires between the home telephone block and the
Bypass Board as follows:
a.
On the Bypass Board HOME area, connect the red wire to the tip terminal (marked as
"T") and the green wire to the ring terminal (marked as "R").
b.
Connect the opposite end of these wires to the telephone line entering the house.
See Important Notes on following page.
Rev B
Figure 5. Bypass Board Hookup (Standard).
Figure 6. Bypass Board Connections (Standard).
Doc. 6001145
Page 9 of 25