Adjustments - Joannes EPOCA 25-29 NS Installation And Maintenance Manual

Wall-hung gas instantaneous condensing boiler
Table of Contents

Advertisement

Button
ON/OFF
RIARMO/RESET
PROG./MODE

ADJUSTMENTS

ADJUSTING HOT WATER TEMPERATURE
1) Open a hot water tap (temporarily).
2) Press (MODE). An indicator light on the left-hand
display comes on.
3) Press (STEP) to phase 1
4) Press the (+) (-) buttons to modify the hot water
temperature.
5) Press (STORE) to memorise the data.
6) Press (MODE) twice to enter the new temperature
setting.
The boiler is ready to function for heating and hot water supply.
Function
ON/OFF SWITCH
SUMMER/WINTER SWITCH
BOILER RESET
PROGRAM SELECTOR
(DISPLAY)
Button
SEQUENZA/STEP
MEMO/STORE
+
-
ADJUSTING HEATING TEMPERATURE
1) Press (MODE). An indicator light on the left-hand
display comes on.
2) Press (STEP) to phase 4
3) Press the (+) (-) buttons to modify the heating tem-
perature setting.
4) Press (STORE) to memorise the data.
5) Press (MODE) twice to enter the new temperature
setting.
Function
SELECTS PARAMETERS TO BE
DISPLAYED
ENTERS DATA
INCREASES SETTING
DECREASES SETTING