List Of Parameters Indicated By 1; St Figure On Display - Joannes EPOCA 25-29 NS Installation And Maintenance Manual

Wall-hung gas instantaneous condensing boiler
Table of Contents

Advertisement

LIST OF PARAMETERS INDICATED BY 1

To gain access to the PHASE number press the MODE button once (an indicator light to the right of the 1
comes on). Press STEP to display all the available PHASES.
Example:
°
Phase N
Hot water temperature
1
Hot water system
2
3
Heating
Water delivery temperature
4
To exit the PHASE list press
FIGURE ON DISPLAY (Values can be adjusted by the user)
st
Step
N° display
Parameter
twice.
Parameter value
display
indicator light
Value range
from 40 to 65 °C
00 = domestic hot water excluded
01 = 5°C hysteresis + pump
continuously on Hot water
02 = 5°C hysteresis
03 = 10°C hysteresis
04 = 20°C hysteresis
05 = 30°C hysteresis
00 = heating disabled
01 = heating enabled
02 = heating enabled, pump
running continuously
from 20 to 90°C
66
figure
st
Default settings
55
02
01
80