Fuses and Circuit Breaker

One 5 amp., two 15 amp. fuses, and a fusible link are
incorporated for the protection of the entire wiring circuit.
The link can be replaced if total loss of electrical function
results. They are located under the control panel to the right
of the seat (Fig. 53). If total loss of electrical function
occurs, find and correct the malfunction before replacing
the fusible link.
Figure 53
1. Fuse block
Important
Do not install fuses in fuse block on left side
of instrument control panel. Fuses should be installed in
this fuse block only if machine is equipped with a road
light kit.

Servicing the Brake System

Check brake fluid level every 50 hours operation. Replace
fluid every 1000 hours operation, or yearly. Replenish
system with DOT 3 hydraulic brake fluid. To check fluid
level:
1. Raise floor panel in front of seat (Fig. 54). Remove tool
tray.
1
1. Floor plate
2. Snap cover bail off cover and remove cover from
master cylinder (Fig. 55).
1. Master cylinder
2. Cover bail

Wheels and Tires

Torque Wheel Nuts
After the first ten (10) hours operation, check torque on the
wheel nuts and every 200 hours thereafter.
1. Torque lug nuts for front wheels 60–70 ft.-lb.
(81–95 N m).
2. Torque lug nuts for rear wheels to 30–35 ft.-lb.
(41–47 N m).