4. Clean the area around the filler neck of the hydraulic
tank and remove the cap from the filler neck
(Figure 17).
Figure 17
1. Filler neck cap
5. Check the fluid level on the dipstick (Figure 18).
The fluid level should be between the marks on the
dipstick.
Figure 18
1. Dipstick
6. If the level is low, add enough fluid to raise it to the
proper level.
7. Install the cap on the filler neck.
Starting and Stopping the
Engine
Starting the Engine
1. Ensure that the auxiliary hydraulics lever is in
neutral.
2. Move the throttle lever midway between Slow and
Fast positions.
3. Move the choke lever to the On position.
Note: A warm or hot engine may not require
choking.
4. Turn the ignition key to the Start position
(Figure 21). When the engines starts, release the key.
Important: Do not engage the starter for more
than 10 seconds at a time. If the engine fails
to start, allow a 30 second cool-down period
between attempts. Failure to follow these
instructions can burn out the starter motor.
5. Gradually move the choke lever to the Off position
(Figure 22). If the engine stalls or hesitates, engage
the choke again until the engine warms up.