ABOUT THESE FANS
Tri-Lite HVLS fans blanket a very large area by constantly moving air to
create an expansive comfort zone. As a result, the big ceiling fan can
create an evaporative cooling effect of three to four degrees Celsius
throughout the facility.
During the heating season, the Tri-Lite HVLS  fan technology can
de-stratify uneven temperatures that can be in excess of fifteen
degrees Celsius from ceiling to floor. This results in significant energy
savings since heating system cycles less frequently.
THE TUBERCLE ADVANTAGE
Tubercle Technology™ blades outperform all conventional airfoils.
They accomplish this by:
• Offering stall angles as high as 22°. Airfoil blades without whale technology stall at 8 degrees so whale power allows for much more air
movement with fewer blades.
• Eliminating span-wise pumping; the primary cause of efficiency loss in all rotating systems.
• Eliminating tip stalling; the primary cause of blade noise and damaging vibration.
• Lowering noise by offering Tubercle Technology's™ hyper-stability which also lowers vibrations which cause wear and tear on the blades
and drive train.
THE BENEFITS OF TRI-LITE HVLS FANS
• Quiet speed and efficient operation, no annoying high speed circulating and exhaust fans.
• Virtually maintenance free (recommended inspection every 20,000 hours).
• Inexpensive to operate.
• Greatly reduces "recovery" time when overhead doors are open with a constant air flow throughout the space.
• Provides a constant, even temperature from floor to ceiling and wall to wall.
• Will minimize the need for expensive duct work in new construction for both heating and air conditioning systems.
• A comfortable workplace environment increases productivity and decreases absenteeism.
HVLS fans provide many benefits for many applications, such as:
For hot months where air conditioning is not available, or not affordable, a HVLS fan moves the air above the minimum speeds that break
up the moisture saturated layer surrounding the human body. The evaporation happens faster, which provides a cooling effect often referred
to as "windchill". This creates a comfortable workplace and increases productivity.
For large sparsely populated warehouses, or open and un-insulated buildings where air conditioning would be wasteful and pointless
For instances where fumes and smoke are produced from welding, forging, painting, etc. and the continuous ventilation of the HVLS dilutes
the air.
For renovations where moving duct work is not feasible, or in new installs where ductwork would be expensive and time-consuming, a HVLS
can be installed to compensate.
The HVLS is quiet and operates efficiently, no annoying high speed circulating or exhaust fans that sometimes direct too much air in a small
area.
The HVLS is virtually maintenance free! (recommended inspection every 20,000 hours).
The HVLS is inexpensive to operate(0.75 kW Gear Motor).
The HVLS greatly reduces "recovery" time when overhead doors are open, working like an air curtain, the inside air is kept inside, and the
outside air is blocked with a constant airflow throughout the space.
For heated buildings where a large amount of heat is trapped at the ceiling. HVLS fans destratify the air by continually circulating the warm
air from the ceiling back to the floor along the outside wall without creating a windchill by operating in reverse and reducing heating costs
by up to 30%. See Figure 1 and 2.
TRI-LITE HVLS-DESIGN & ENGINEERING GUIDE (04/16)
Subject to change without notice.
Page 1 of 17

Advertisement

Table of Contents
loading

Summary of Contents for Canarm Tri-Lite HVLS SERIES

  • Page 1 TRI-LITE HVLS SERIES CEILING FANS DESIGN &  ENGINEERING GUIDE PLEASE READ AND SAVE THIS GUIDE ABOUT THESE FANS Tri-Lite HVLS fans blanket a very large area by constantly moving air to create an expansive comfort zone. As a result, the big ceiling fan can create an evaporative cooling effect of three to four degrees Celsius throughout the facility.
  • Page 2 CALCULATING AIRFLOW OF HVLS INSTALLED AT CANARM FACILITY At Canarm’s Corporate Office(and manufacturing facility), an HVLS-24 was installed above our assembly lines. A series of tests were conducted to calculate the total airflow(CFM) and to determine fan layout. Below are the results.
  • Page 3 TRI-LITE HVLS SERIES FANS VERTICAL AIRFLOW MEASURED A calibrated anemometer was used to calculate the various airspeeds at locations concentric to the center of the HVLS fan. The anemometer was held 4 feet above the ground(14 feet below the HVLS) and an average airspeed(through 30 seconds) was recorded at the predetermined distances from center.
  • Page 4 TRI-LITE HVLS SERIES FANS Using the recorded values of Air Speed at the specified distances, the average was taken and applied to the square footage of coverage to find the total CFM. Calculated average air movement 14 feet from the HVLS fan is 334,445 CFM.
  • Page 5 TRI-LITE HVLS SERIES FANS HORIZONTAL AIRFLOW MEASURED A calibrated anemometer was used to calculate the various airspeeds at locations concentric to the center of the HVLS fan. The anemometer was held 2 feet above the ground(16 feet below the HVLS) and an average airspeed(through 30 seconds) was recorded at the predetermined distances from center.
  • Page 6: Fan Layout

    The following diagrams illustrate locations of the HVLS fans and how the air moves in relation to the fans location. It is recommended to contact Canarm for assistance in layout to ensure the fans are utilized properly. In some cases circulating fans may be required to assist the air movement to specific locations in your installation, the specialists at Canarm can help! Subject to change without notice.
  • Page 7 TRI-LITE HVLS SERIES FANS Figure 9 Air blocked by racking < < " Figure 10 Air blocked by racking Subject to change without notice. TRI-LITE HVLS-DESIGN & ENGINEERING GUIDE (04/16) Page 7 of 17...
  • Page 8 TRI-LITE HVLS SERIES FANS Figure 11   Obstructions will affect airflow  Providing as much detail as possible will assist in the most efficient layout   for your application 350-500 FPM 300-350 FPM 250-300 FPM 100-250 FPM...
  • Page 9: Installation

    TRI-LITE HVLS SERIES FANS INSTALLATION Tri-Lite HVLS fans come as a complete system including power unit, mounting hardware, wiring kit (optional) and low voltage controller (optional). Having everything included in this complete package streamlines installation and eliminates the costly search for components and hardware.
  • Page 10: Fan Components

    TRI-LITE HVLS SERIES FANS FAN COMPONENTS See Cable Detail Drawing Subject to change without notice. TRI-LITE HVLS-DESIGN & ENGINEERING GUIDE (04/16) Page 10 of 17...
  • Page 11: Specifications

    TRI-LITE HVLS SERIES FANS SPECIFICATIONS HVLS-16230460-1HP (16’) DIMENSIONS General Model Number ..................HVLS-16230460-1HP Diameter ..........................16’ Blade ................Whale Power Tubercle Technology™ Number of Blades ........................ 3 Motor Power ....................0.75 kW (1 Hp) Noise level ........................62 dBA Weight (no mount) ..................... 168 lbs* Packaged Fan- 60 em x 60 em x 73 em ..............
  • Page 12 TRI-LITE HVLS SERIES FANS SPECIFICATIONS HVLS-24230460-1HP (24’) DIMENSIONS General Model Number ....................HVLS-24230460 Diameter ..........................24' Blade ................Whale Power Tubercle Technology™ Number of Blades ........................3 Motor Power ....................0.75 kW (1 Hp) Noise Level ........................ 57 dBA Weight (no mount) ....................199 lbs* Packaged Fan - 60 em x 60 em x 73 em .
  • Page 13 TRI-LITE HVLS SERIES FANS DIFFERENT MOUNTING I BEAM MOUNTING OWSJ MOUNTING APPLICATIONS NOTE: The following mounting applications are representations only and are subject to change without notice. Contact your Canarm sales representative for complete mounting instructions. WOOD BEAM MOUNTING CONCRETE BEAM MOUNTING PURLIN “Z”...
  • Page 14 TRI-LITE HVLS SERIES FANS MOUNTS 1 FT UMH MOUNT ITEM # MODEL # DESCRIPTION QTY. EN823X8425 DROP H TYPE 1 FT EN823x8418 UMH COUPLER PC EN823x8417 UMH UPPER PIVOT PLATE EN823X8401 MANUFACTURED I-BEAM SPACER EN823x8402 MANUFACTURED I-BEAM CLAMP Subject to change without notice.
  • Page 15 TRI-LITE HVLS SERIES FANS EXTENSION MOUNTS 2 FT PKG EXTENSION MOUNT 4 FT PKG EXTENSION MOUNT NUT NYLOCK x 4 EXTENSION EXTENSION x 1 BOLT x 4 BOLT x 4 WASHER x 4 WASHER x 4 NUT NYLOCK x 4 24”...
  • Page 16: Safety & Installation

    TRI-LITE HVLS SERIES FANS FAN CONTROL WIRE CONNECTIONS TO VFD 2HP 230V NEMA 4 VFD (Variable Frequency Drives) 6.28” 5.90” 6.31” .66” External ntrol Control (Optional) 6.56” 8.00” Wire Wire From To Fan AC  Supply Ground Wire 1.50” 1.50” Minimum 11.8”...
  • Page 17: Packaging Details

    Input (NEMA4) INSTALLATION OR PRODUCT PROBLEMS? Do not return to store of purchase. Contact Canarm at 1-800-265-1833 (CANADA), 1-800-267-4427 (U.S.A.), 1-800-567-2513 (EN FRANCAIS) Monday to Friday 8:00 - 5:00pm e.s.t. or visit www.canarm.com Canarm Ltd. - Corporate Office 2157 Parkedale Avenue, PO Box 367 Brockville, Ontario Canada K6V 5V6 Tel: (613) 342-5424;...

Table of Contents