Toshiba RAS-4M27S3AV-E Service Manual page 46

Table of Contents

Advertisement

<Heating> (Continued)
No. of
Temperature condition
operating
Indoor
Outdoor
units
3 units
20/-
7/6
4 units
NOTES:
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor
thermometer)
2. Connecting piping condition : 5 meters × 4 units (5 m / each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
P (MP)
22
16
07
-
2.5 to 2.7
24
16
07
-
2.5 to 2.7
18
18
07
-
2.5 to 2.7
22
18
07
-
2.5 to 2.7
24
18
07
-
2.5 to 2.7
10
10
10
-
2.3 to 2.5
13
10
10
-
2.3 to 2.5
16
10
10
-
2.5 to 2.7
18
10
10
-
2.5 to 2.7
22
10
10
-
2.5 to 2.7
24
10
10
-
2.5 to 2.7
13
13
10
-
2.5 to 2.7
16
13
10
-
2.5 to 2.7
18
13
10
-
2.5 to 2.7
22
13
10
-
2.5 to 2.7
24
13
10
-
2.5 to 2.7
16
16
10
-
2.5 to 2.7
18
16
10
-
2.5 to 2.7
22
16
10
-
2.5 to 2.7
24
16
10
-
2.5 to 2.7
18
18
10
-
2.5 to 2.7
22
18
10
-
2.5 to 2.7
24
18
10
-
2.5 to 2.7
13
13
13
-
2.5 to 2.7
16
13
13
-
2.5 to 2.7
18
13
13
-
2.5 to 2.7
22
13
13
-
2.5 to 2.7
24
13
13
-
2.5 to 2.7
16
16
13
-
2.5 to 2.7
18
16
13
-
2.5 to 2.7
22
16
13
-
2.5 to 2.7
24
16
13
-
2.5 to 2.7
18
18
13
-
2.5 to 2.7
22
18
13
-
2.5 to 2.7
16
16
16
-
2.5 to 2.7
22
16
16
-
2.5 to 2.7
07
07
07
07
2.2 to 2.4
10
07
07
07
2.2 to 2.4
13
07
07
07
2.2 to 2.4
16
07
07
07
2.2 to 2.4
18
07
07
07
2.2 to 2.4
22
07
07
07
2.2 to 2.4
24
07
07
07
2.2 to 2.4
10
10
07
07
2.2 to 2.4
13
10
07
07
2.2 to 2.4
16
10
07
07
2.2 to 2.4
18
10
07
07
2.2 to 2.4
22
10
07
07
2.2 to 2.4
24
10
07
07
2.2 to 2.4
13
13
07
07
2.2 to 2.4
Heat exchanger
pipe temperature
T1 (ºC)
T2 (ºC)
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
38 to 40
-1 to 1
38 to 40
-1 to 1
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
33 to 35
-2 to 0
- 46 -
FILE NO. SVM-15073
Compressor
Indoor fan
Outdoor fan
revolution
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
(rps)
73.0
73.0
73.0
73.0
73.0
71.8
72.2
72.4
72.6
72.8
73.0
72.6
72.8
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0