<Cooling> (Continued)
No. of
Temperature condition
operating
Indoor
Outdoor
units
4 units
27/19
35/-
NOTES:
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor
thermometer)
2. Connecting piping condition : 5 meters × 4 units (5 m / each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
P (MP)
13
13
07
07
1.0 to 1.2
16
13
07
07
1.0 to 1.2
18
13
07
07
1.0 to 1.2
22
13
07
07
1.0 to 1.2
24
13
07
07
1.0 to 1.2
16
16
07
07
1.0 to 1.2
18
16
07
07
1.0 to 1.2
18
18
07
07
1.0 to 1.2
10
10
10
07
1.0 to 1.2
13
10
10
07
1.0 to 1.2
16
10
10
07
1.0 to 1.2
18
10
10
07
1.0 to 1.2
22
10
10
07
1.0 to 1.2
24
10
10
07
1.0 to 1.2
13
13
10
07
1.0 to 1.2
16
13
10
07
1.0 to 1.2
18
13
10
07
1.0 to 1.2
22
13
10
07
1.0 to 1.2
24
13
10
07
1.0 to 1.2
16
16
10
07
1.0 to 1.2
18
16
10
07
1.0 to 1.2
18
18
10
07
1.0 to 1.2
13
13
13
07
1.0 to 1.2
16
13
13
07
1.0 to 1.2
18
13
13
07
1.0 to 1.2
16
16
13
07
1.0 to 1.2
18
16
13
07
1.0 to 1.2
10
10
10
10
1.0 to 1.2
13
10
10
10
1.0 to 1.2
16
10
10
10
1.0 to 1.2
18
10
10
10
1.0 to 1.2
22
10
10
10
1.0 to 1.2
24
10
10
10
1.0 to 1.2
13
13
10
10
1.0 to 1.2
16
13
10
10
1.0 to 1.2
16
16
10
10
1.0 to 1.2
18
13
10
10
1.0 to 1.2
18
16
10
10
1.0 to 1.2
13
13
13
10
1.0 to 1.2
16
13
13
10
1.0 to 1.2
18
13
13
10
1.0 to 1.2
13
13
13
13
1.0 to 1.2
Heat exchanger
pipe temperature
T1 (ºC)
T2 (ºC)
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
- 44 -
FILE NO. SVM-15073
Compressor
Indoor fan
Outdoor fan
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
revolution
(rps)
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-4m27s3av-aRas-4m27s3av-tr

Table of Contents