Repeater Units; General Specifications - Omron C-series Installation Manual

Link adapters
Hide thumbs Also See for C-series:
Table of Contents

Advertisement

General Specifications

1-3

Repeater Units

1-4
General Specifications
Link Adapters
Model
Function
AL001
Branching RS-422 cable
AL002-PE
Branching optical fiber
(APF/PCF) cable
AL002-E
Branching optical fiber
(PCF) cable
AL004-PE
Converting between opti-
cal fiber (APC/PCF) and
wire (RS-232C/RS-422)
cable
AL004-E
Converting between opti-
cal fiber (PCF) and wire
(RS-232C/RS-422) cable
AL005-PE
Converting between opti-
cal fiber (APF/PCF) and
crystal optical fiber
(AGF) cable
AL005-E
Converting between opti-
cal fiber (PCF) and crys-
tal optical fiber (AGF)
cable
AL006-PE
Converting between opti-
cal fiber (APF/PCF) and
crystal optical fiber
(AGF) cable
AL006-E
Converting between opti-
cal fiber (PCF) and crys-
tal optical fiber (AGF)
cable
AL007-P
Used exclusively for
Wired Remote I/O Sys-
tems. Converts between
optical fiber (APF/PCF)
and wire (RS-485) cable
Repeater Units are used when the number of Optical Transmitting I/O Units, Op-
tical Slave Racks, etc., connected in series exceeds 32. Insertion of a Repeater
Unit after the 32nd Unit allows the connection of additional Units. The following
Repeater Units are used with the cables shown here:
Applicable Cables
Model
3G2A9-RPT01-P
APF/PCF
3G2A9-RPT01
PCF
APF: All-plastic optical fiber cable
PCF: Plastic-clad optical fiber cable
Basic specifications for the Link Adapters and Repeater Units are shown in the
following table:
Connection
RS–422 cable
RS-422
cab;e
Optical fiber (APF/PCF)
Optical fiber
(APP/PCF)
Optical fiber (PCF)
Optical fiber
(PCF)
RS–422 cable
Optical fiber
(APF/PCF)
RS–422 cable
Optical fiber
(PCF)
Optical fiber (APF/PCF)
Optical fiber
(AGF)
Optical fiber (PCF)
Optical fiber
(AGF)
Optical fiber (AGF)
Optical fibber
(APF/PCF)
Optical fiber (AGF)
Optical fiber
(PCF)
Optical fiber
(APF/PCF)
APF: All-plastic optical fiber cable
PCF: Plastic-clad optical fiber cable
AGF: Crystal optical fiber cable (GI 50 or 125)
Supply voltage
Not necessary
RS-422
cable
100 to 120/200
85 to 132/170 to
to 240 VAC or
246 VAC or 10.2
12 to 24 VAC/
to 26.4 VAC/DC
Optical fiber
DC
(APF/PCF)
Optical fiber
(PCF)
110 to 120/
94 to 132/
220 to 240 VAC
187 to 264 VAC
RS-232C
cable
RS-232
cable
100 to 120/200
85 to 132/170 to
to 240 VAC or
254 VAC or 10.2
12 to 24 VAC/
to 26.4 VAC/DC
DC
100 to 120/200
85 to 132/170 to
to 240 VAC or
264 VAC or 10.2
12 to 24 VAC/
to 26.4 VAC/DC
Optical fiber
DC
(AGF)
Optical fiber
(AGF)
100 to 200 VAC
85 to 264 VAC
RS-485
Section
Operating
Power
Weight
voltage range
consumption
---
---
250 g
max.
10 VA max.
900 g
max.
10 VA max.
1 kg
max.
10 VA max.
1.5 kg
max.
10 VA max.
1.5 kg
max.
10 VA max.
1 kg
max.
1-4