Specifications; Series Connection Types - Omron F3S-B Specification Sheet

Safety light curtain
Hide thumbs Also See for F3S-B:
Table of Contents

Advertisement

F3S-B
J STAND-ALONE TYPE
This is the most common configuration, and it is used to
protect a hazardous part of a machine when approached
from one direction only.
Receiver
Indicator area
Extension cable

Specifications

J RATING AND PERFORMANCE
Type
F3S-BjjjP (See Note 1.)
Stand-Alone
No. of optical axes
12 to 66
(Beams)
Optical-axis pitch
25 mm
(Beam pitch)
Optical resolution
Non-transparent: in diameter
(Detection
(Detection
30 mm
capability)
1
Note:
For detailed type names and optical specifications, see Ordering Information.
Emitter
F3S-BMjjjPjj (See Note 1.)
Master Unit for series connection
6 to 33
4 to 22
12 to 66
50 mm
75 mm
25 mm
55 mm
80 mm
30 mm
(This table continues on the next page.)
J SERIES CONNECTION TYPES
When your application requires an additional protective zone,
for example, to prevent someone from staying behind a primary
detection zone, the F3S-B may be connected in series. The
system consists of a Master Unit, a Slave Unit, and a series
connection cable, type F39-JB1B.
The series connection allows up to 96 axes and 2.4 m of
protective height in total.
Series connection types have the same characteristics as
stand-alone types. When the detection zone of the Master Unit
or that of the Slave Unit is interrupted, the outputs of the Master
Unit go to the OFF-state.
Note: Slave Unit does not have indicators.
Master Unit and Slave Unit need to be ordered
separately.
Slave Unit
Master Unit
6 to 33
4 to 22
50 mm
75 mm
55 mm
80 mm
4
Protective height
Series connection cable
Protective height
Indicator area
Extension cable
F3S-Bjjj (See Note 1.)
Master Unit for series connection
12 to 30
6 to 15
4 to 10
25 mm
50 mm
75 mm
30 mm
55 mm
80 mm

Advertisement

Table of Contents
loading

Table of Contents