Storing the Battery
If the machine will be stored more than 30 days, remove
the battery and charge it fully. Either store it on the shelf on
the machine. Leave the cables disconnected if it is stored on
the machine. Store the battery in a cool atmosphere to
avoid quick deterioration of the charge in the battery. To
prevent the battery from freezing, make sure it is fully
charged. The specific gravity of a fully charged battery is
1.265–1.299.
Servicing the Wiring Harness
Prevent corrosion of wiring terminals by applying Grafo
112X (Skin-over) grease, Toro Part No. 505-47, to the
inside of all harness connectors whenever the harness is
replaced.
Whenever working with the electrical system, always
disconnect battery cables, negative (–) cable first, to
prevent possible wiring damage from short-outs.
Hydraulic Schematic
Servicing the Fuses
Fuses are located under the control panel (Fig. 52).
1. Fuse block