Water Supplies - Rheem 610340 Owner's Manual And Installation Instructions

Commercial storage tank
Hide thumbs Also See for 610340:
Table of Contents

Advertisement

This storage tank must be installed in accordance with this advice to be covered by the Rheem
warranty.
This storage tank is manufactured to suit the water conditions of most public reticulated water supplies.
However, there are some known water chemistries which can have detrimental effects on the storage tank
and its operation and / or life expectancy. If you are unsure of your water chemistry, you may be able to
obtain information from your local water supply authority. This storage tank should only be connected to a
water supply which complies with these guidelines for the Rheem warranty to apply.
CHANGE OF WATER SUPPLY
The changing or alternating from one water supply to another can have a detrimental effect on the operation
and / or life expectation of a storage tank cylinder and a temperature pressure relief valve.
Where there is a changeover from one water supply to another, e.g. a rainwater tank supply, bore water
supply, desalinated water supply, public reticulated water supply or water brought in from another supply,
then water chemistry information should be sought from the supplier or it should be tested to ensure the
water supply meets the requirements given in these guidelines for the Rheem warranty to apply.
ANODE
The vitreous enamel lined cylinder of the storage tank is only covered by the Rheem warranty when the total
dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode
is used. If an incorrect colour coded anode is used in the storage tank, any resultant faults will not be covered
by the Rheem warranty. In addition, the use of an incorrect colour coded anode may shorten the life of the
storage tank cylinder.
The correct colour coded anode must be selected and fitted to the storage tank in accordance with the
following advice and the
cylinder.
The changing of an anode must be carried out by a qualified person.
Note: Some water analysis reports may state the conductivity of the water rather than the level of total
dissolved solids. Conductivity, measured in microsiemens per centimetre (µS / cm), is directly proportional to
the TDS content of the water. TDS, in mg / L, is approximately 70% of the conductivity in µS / cm.
40
150
(60)
(215)
Green
Black

WATER SUPPLIES

Anode Selection chart
on page 9 for the Rheem warranty to apply to the storage tank
Total Dissolved Solids
0 – 40 mg/L
40 – 150 mg/L
150 – 400 mg/L
400 – 600 mg/L
600 – 2500 mg/L
2500 mg/L +
400
600
TOTAL DISSOLVED SOLIDS (TDS) mg/L
(CONDUCTIVITY - μS/cm)
(570)
(860)
Warranty applies to a vitreous-enamel-lined
water heater cylinder if the correct coloured
anode is used for the TDS of the water
ANODE SELECTION
Anode colour code
Green
Green or Black
Black
Black or Blue
Blue
Blue (no cylinder warranty)
Blue
9
2500
(3570)
Blue
Above 2500 mg/L,
no warranty applies
to a vitreous-
enamel-lined water
heater cylinder

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

610430

Table of Contents